Browse : A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z  
Featured Products 

Corrosion Inhibitor-44

Corrosion Inhibitor FILMMAX

Product Description | Product Application | Product Notes| Product DOSE
RXSOL-50-5005-025  Concentrated liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great prote [+] Read More...
Code:
RXSOL-44-5005-200
Other Equivalent Brand

Green CC, RXSOL 9-150 / SLCC-A, Care Treat-4, MARICHEM C.C.I.TM, CCT 102, Maxtreat 3330, DM-530, Condensate Treatment 9-150, BWT QC4, pH CONTROLLER AMINE bas. Amerzine, NEUTRALIZING AMINE AGENT JCF 2005 RP-01A, Aquameen 1150D, Condensate Control 210 Ltr, HP-FILMMAX, Overhead Toping System Corrosion Inhibitor Insoluble

Short Description:
Insoluble concentrated liquid neutralising agent for corrosion control in toping overhead system of crude distillation, contains blends of low, medium and high volatility amines that provide great protection and neutralization of acids and acidic gases, such as CO2
Generic Name:
Insoluble neutralising agent for corrosion control in toping overhead system of crude distillation
Active Matter:
88 - 93 %
IMPA Code:
551444
Corrosion Inhibitor FILMMAX
Application:
RXSOL-50-5005-025 is a blend of volatile liquid / steam distributions ratios that neutralise the acid contaminants in condensate and feed water thus providing protection against acid corrosion in the [+] Read More...
Using Procedure:
RXSOL-50-5005-025 condensate is tested for PH to determine the dosage level. The PH limits are 8.3 - 9.0 . For an average system e. g. 10-M3, the dosage is approximately 0.65 ltr / day . The necessary am [+] Read More...
Note:
Advantages of using Corrosion Inhibitor FILMMAX in overhead toping systems Easy to use liquid treatment. Neutralizes the acids occurring in the condensate system. Less maintena [+] Read More...
Technical Specifications:

We carry a complete line of condensate treatment chemicals.  Condensate treatment chemicals are used to increase the condensate pH, thus reducing corrosion to the entire boiler steam system.  The most common product is a tri-blend amine of cyclohexylamine, morpholine, and diethylaminoethanol (DEAE) neutralizing amines, although we do have standard RXSOL products or we can custom blend to your needs.
RXSOL-50-5005-DCM1          10% DEAE, 10% Cyclo, 10% Morpholine   
RXSOL-50-5005-DCM2          20% DEAE, 20% Cyclo, 20% Morpholine   
RXSOL-50-5005-C                  20% Cyclohexylamine    
RXSOL-50-5005-D                  20% DEAE    
RXSOL-50-5005-M                  20% Morpholine   
RXSOL-50-5005-C5                50% Cyclohexylamine    
RXSOL-50-5005-D                  50% DEAE  
RXSOL-50-5005-M5                50% Morpholine    
  

PRODUCT INTRODUCTION
Pure anisole or methoxybenzene, is an organic compound. CAS NO: 100-66-3
HANDLING & STORAGE
Keep away from heat and sources of ignition.
Store in a sealed condition at ambient temperature or below. Keep containers in tightly closed condition.
Use proper PPE during handling.
PRODUCT APPLICATION
Used as solvent, as an intermediate in making of dyes, pharmaceuticals, fragrances and as an insect pheromones.
PROPERTIES
Appearance
Clear Colorless Liquid
Purity ( by GC ) , %
99.8 Min
Specific Gravity @25°C
0.9995 ± 0.05
Moisture (by KF) , %
0.3 Max
PACKAGING
Packed in drums or in ISO TANKS on request.

 
 

Remarks:

RXSOL-50-5005-025 alkaline and the vapors are irritating to eyes and lungs. Avoid contact with eyes and skin. Do not take internally. Observe safety regulations wear Goggles, PVC gloves and Apron when handling Provide ample ventilation Avoid contact with skin in case of contacts wash with cupious amount of water immediately. If eyes are splashed give immediate and prolonged irrigation with clean running water and obtain medical attention.

Not for internal use :-
If swallowed do not induce vomiting give plenty of water or milk and call a doctor immediately.

Packing. GENERAL REMARKS:-Do not store  RXSOL-50-5005-025  near a heating equipment.

Why Condesate control ( Condensnol Amine ) required as BOILER Water Treatment chemicals?

Condensate control plays very important role to neutralize Acidic nature of boiler water steam during condensation process. As acidic nature rapidly corroding metal body of BOILER and surrounding system.


What is the main base and chemical principle of Condensate Control (Condensnol Amine )?

Condensate control contain mixture of condensnol amine which helps to neutralize acidic media which causes corrosion in boiler system. On the other hand we can say that condensate control works as a corrosion controler in steam and condensate systems.

Is Condensate System can be kept safe by using Condensnol amine - condensate Control?
 

Condesnol Amine ihighly effective product to CONTROL acidic strength of CONDENSATE SYSTEM. During liquid treatment Condensnol amine neutralises the acids in the condensate system.

Is Condensate control is easy to use?

RXSOL-50-5005-025 condensate is tested for PH to determine the dosage level. The PH limits are 8.3 - 9.0 . For an average system e. g. 10-M3, the dosage is approximately 0.65 ltr / day .

The necessary amount of RXSOL-50-5005-025 is required or injected as frequently as to maintain the pH of the condensate at the main condensate pump outlet between 8.6-9.5 .  The amines pass over with the steam and have the dual function of elevating the pH of the steam/condensate and putting a protective micro film on the system pipe work. Acidic condensate is the result of carbonic acid (H2CO3) being formed as CO2 is released in the steam.Condensate prevents corrosion by carbonic acid on live systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are present.
 

How Condensate control works?

Condensate control contains volatile amine which helps to neutralising the acidic contaminants pH of the system and keep the whole boiler and condenser system workable in good running condition for future use.

The condensate system contains high level of carbon dioxide in presence of vaporized steam the rapid formation of carbonic acid takes place which corrodes the metalic content rapidly.
 
Condensate control cuts down such formation and facilitates in maintaining favourable environment for metalic parts. The dosage of condensate control depends on the aggregate carbonic acid content and should be added till the point the pH range is 8.3 to 9.
 
Corrosion in the overhead system of the crude distillation unit is caused by hydrogen chloride produced by hydrolysis of chloride salts found in crude oil. The desalter unit in the refineriestypically removes salts and the escaped salts are hydrolyzed to produce the corrosive HCl gas. To mitigate the corrosion caused by HCl gas, neutralizing amines and film forming amines are dosed at overhead section of the crude unit. RXSOL has developed the filming amine formulations (Corrosion Inhibitor FILMMAX).
 
The mechanism includes formation of a film which can act as a hydrophobic barrier  against corrosive species, such as, HCl. Film forming amine formulations typically contain two components, namely,
(i) neutralizing amines to control the pH and
(ii) Long chain alkyl amine to form a protective film.
 
The major desirable characteristics of any film forming amine formulations includes high temperature pH control, corrosion mitigation and strong fill formation. Accordingly, the in-house developed formulations were evaluated for pH neutralization, solubility, rotating cage corrosion rate and QCM film strength. The best identified formulation have been scaled up to 9 MT for field trials. During the trials, the Corrosion Inhibitor FILMMAX met the required specifications less than 0.3 ppm of iron content in the stream.
 

#BoilerWATERtreatment_AlkalinityControl
#BoilerCHEMICAL_UAEdubai
#boilerWATERtreatment_MuscatOMAN

#CorrosionInhibitorforOverheadTopingSystem

Condesate Control supply and Stock location.
We are one of largest condensate control manufacturer and supplier in Kolkata - Haldia - Paradip, Mumbai - JNPT - Pirpav - Chembur, Chennai - Ennore, Visakhapatnam - Gangavaram, Kandla, Mundra, Sikka, Salaya, NAvlakhi, Surat - Hazira, Fujairah, Dubai, Abu Dhabi, Sharjah

Protection of Condenser from Corrosion in Boiler / Power plant.

Condenser  and its related accessory like condensate pump protection from corrosion is important task to avoid high maintenance cost due to acidic cavitation which can cause plant unplanned downtime. Unnecessary condenser maintenance also effect production yield.

What is condenser?

Condenser helps to condensate high temperature steam to water which can be collected and returned to further utilize in the steam generator. During condensation condensate control works during super heated temperature steam to neutralize or prohibit acid formation which is causes of cavitation and rusting etc...

Benefit of uses of Condensate Control - Condensnol amine?

Save maintenance cost
Avoid down time of system.

Increase production yield.
Acidic medium causes rust / cavitaion which is resulting more vibration of motor plant machiner, Condensnol Amine uses effectively neutralizes Acid during condensation.
Corrosion Inhibitor FILMMAX
:
Packing Size:
210.00 Ltr.
Available Packing Size:
20, 25, 35, 50, 210 Ltrs Mail us to get factory sale discounted price. Amines that provide great protection and neutralization of acidic gases, Corrosion control in condensate and feed water systems. Protects boiler surfaces by forming an iron tannate film.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Concrete Pipeline Powder

Product Description | Product Application | Product Notes| Product DOSE
RXSOL CPLP Concrete Pipeline Lubricant Powder is concrete delivery truck mortar releasing solution.   RXSOL CPLP Lubricant helps concrete transport company  to save time to release mortar from vechicle and also helps to keep vehicle  mortar deposition free.
Code:
RXSOL-67-6713-200
Other Equivalent Brand

Lubricant for Concrete Pipeline, RXSOL CPLP

Short Description:
Concrete lubricant for application of used in pipeline of concrete pump
Generic Name:
Lubricant for Concrete Pipeline
Active Matter:
98-99
Concrete Pipeline Powder
Application:
Concrete pump line inwall is smeared irregularly when pumping, influence result of use, causes pump line to stop up easily, does not reach the effect that mortar moistens pipe,  RXSOL CPLP Concrete Pipeline Lubricant Powder helps as a lubricant to release mortar freely.
Using Procedure:
Take Full container / Pouch of RXSOL CPLP Concrete Pipeline Lubricant Powder   in 50 - 75 Ltr of water, Mix Properly to Get Homogenious Light viscous solution. Then use the RXSOL CPLP water mixed slurry sol [+] Read More...
Note:
RXSOL CPLP Concrete Pipeline Lubricant Powder  enhance concrete flow without block in pipe line. Which is resultig not only TIME SAVER but also protect CIRCULATING SYSTEM and PIPE Line heavy maintenance fr [+] Read More...
Technical Specifications:
Application Method : The RXSOL CPLP lubricant aqueous solution is poured in the truck hopper, and beginning blowing pump concrete will allow the lubricant aqueous solution earlier by pump line when pumping, and concrete pushes pumping in the back, and the lubricant aqueous solution of discharging through pump line comes outside the template, and pumping construction is smooth.
Remarks:

RXSOL CPLP Concrete Pipeline Lubricant Powder Economical to use, very small quantities required for SMOOTH flow.


This lubricant profit that is used for pipeline of concrete pump is managed 50 meters, 

Concrete Pipeline Powder manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Concrete Pipeline Powder at a competitive price from us. We have ready stock of Concrete Pipeline Powder in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.


Concrete Pipeline Powder
:
Packing Size:
200.00 Grams
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Lithium Molybdate

Product Description | Product Application | Product Notes| Product DOSE
Lithium molybdate is used as corrosion inhibitor in LiBr absorption chiller for industrial central air conditioning.
Code:
RXSOL-43-3063-025
Other Equivalent Brand

Li2MoO4, Vapour Absorption Chiller

Short Description:
Lithium molybdate is used as corrosion inhibitor in LiBr absorption chiller for industrial central air conditioning.
Generic Name:
Li2MoO4
Lithium Molybdate
Application:
Lithium Molybdate Solution chemically acts as Corrosion Inhibitor for Central Air Conditioning chiller system. 
Using Procedure:
Lithium bromide as a salt is widely used in absorption and cooling with water. It is used as desiccant in air conditioning system and reagent in organic synthesis.
Note:
Technical Specifications:
Lithium Molybdate Solution
CAS No.: 13568-40-6
Formula: Li2MoO4
EINECS: 236-977-7
Appearance: Liquid
pH Value : 7 - 7.5
Grade Standard: Industrial Grade
Trademark: RXSOL

Lithium Molybdate manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Lithium Molybdate at a competitive price from us. We have ready stock of Lithium Molybdate in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Lithium Molybdate
:
Packing Size:
25.00 Kg
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Acid corrosion Inhibitor RXSOL 213

Product Description | Product Application | Product Notes| Product DOSE
Code:
RXSOL-44-1503-025
Other Equivalent Brand
Short Description:
The addition of Acid corrosion Inhibitor RXSOL 213, inhibitors to hydrochloric acid solution provides maximum protection for equipment during,The removal of lime deposits or water scale from power plant boilers and piping systems and from evaporating equi
Acid corrosion Inhibitor RXSOL 213
Application:
Using Procedure:
Note:
Technical Specifications:
Acid corrosion Inhibitor RXSOL 213
:
Packing Size:
25.00 Ltr.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Corrosion Inhibitor for Central Air Chiller

Product Description | Product Application | Product Notes| Product DOSE
Corrosion Inhibitor for Central Air Chiller used as corrosion inhibitor in LiBr (Lithium bromide) absorption chiller for industrial central air conditioning. It is manufactured and shipped as either [+] Read More...
Code:
RXSOL-44-9001-300
Other Equivalent Brand

Corrosion Inhibitor for Central Air Chiller

Short Description:
Corrosion inhibitor for absorption chiller for industrial central air conditioning
Generic Name:
Air Chiller System Corrosion Inhibitor
Active Matter:
53-55
Corrosion Inhibitor for Central Air Chiller
Application:
It is an absorption chiller for industrial central air conditioning
Using Procedure:
Note:
We are keeping ready stock of Corrosion Inhibitor for Central Air Chiller. We are one of popular supplier of Superior Quality Of Corrosion Inhibitor for Central Air Chiller.
Technical Specifications:
Remarks:

Also keeping ready stock of Lithium Bromide Anhydrous 

CAS No. : 7550-35-8

Molecular Formula : LiBr

Sr Test Specifications
1 Appearance White granular powder
2 Odour Odourless
3 Specific Gravity 3.5 g/cc
4 Water solubility % wt @ 25°C 61
5 PH 7
6 Moisture 0.05% Max.

Lithium Bromide, Lithium Bromide 55% & Lithium Bromide Anhydrous Manufacture and Supply by our company with affordable and compititive price.

LITHIUM SALTS others CAS No
Lithium bromide anhydrous 7550-35-8
Lithium chloride anhydrous 7447-41-8
Lithium chloride solution 40% 7447-41-8
Lithium nitrate anhydrous 7790-69-4
Lithium nitrate solution 40% 7790-69-4
Lithium sulphate anhydrous 10377-48-7
Lithium iodide trihydrate 85017-80-7
Lithium acetate dihydrate 6108-17-4
Lithium acetate anhydrous 6108-17-4
Lithium citrate terahydrate 6080-58-6
Lithium chromate solution 20% 14307-35-8
Lithium fluoride 7789-24-4
Lithium molybdate solution 20% 13568-40-6
 

Corrosion Inhibitor for Central Air Chiller Manufacturer, Supplier and a leading Exporter of Corrosion Inhibitor for Central Air Chiller. We are keeping ready stock of Corrosion Inhibitor for Central Air Chiller solution in Kandla, Mumbai, Chennai, Visakhapatnam, Kolkata, Fujairah, Dubai, Sharjah, Muscat Barka Oman, Kenya Nairobi.

Our other formulating and supplying Inorganic and Organic Compounds of Lithium, Zinc, Nickel, Potassium,Bromides and Iodides. In our range, we offer Iodine Compounds, Iodine Powder, Bromine Compounds, Cupric Bromide, Zinc Iodide, Ammonium Bromide, Cuprous Bromide, Potassium Bromide, Zinc Bromide, Lithium Compounds, Lithium Acetate Di hydrate, Lithium Bromide Solution, Lithium Bromide Anhydrous, Lithium Carbonate, Lithium Chloride Anhydrous, Lithium Chromate Anhydrous, Lithium Chloride Solution, Lithium Chromate Solution, Lithium Citrate Tetra Hydrate, Lithium Fluoro Phosphate, Phenothiazine Compounds, Phenothiazine, Phosphate Compounds, Ferric Phosphate, Lithium Benzoate Anhydrous, Lithium Phosphate, Lithium Acetate Anhydrous, Lithium Sulfate, Lithium Oxalate, Lithium Nitrate Solution, Chemical Compound, Lithium Iodide Tri Hydrate, Lithium Perchlorate, Lithium Stearate.

Corrosion Inhibitor for Central Air Chiller
:
Packing Size:
300.00 Kg.Liq
Available Packing Size:
30 Kg 300 Kg
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

ANTISCALANT 9209 RX Seawater Distillation Plants

Product Description | Product Application | Product Notes| Product DOSE
Antiscalant 9209 RX is specially designed to control the development of scale in seawater distillation plants. It is based on a synergistic blend of phosphonates which are found to be more effective t [+] Read More...
Code:
RXSOL-51-6005-025
Other Equivalent Brand

Hydrex 9209, Metito M 915, Genesys LF

Short Description:
Antiscalant for Water Distillation Units , specially designed to control the development of scale in seawater distillation plants.
Generic Name:
Broad Spectrum Antiscalant and Antifoulant Liquid
Active Matter:
94-98
ANTISCALANT 9209 RX Seawater Distillation Plants
Application:
PREVENTS IRON FOULING and SILICA ANTISCALANT properties. Convenient liquid formulation for automatic dosing using suitable dosing equipment. Prevents formation of hard scale in seawater disti [+] Read More...
Using Procedure:
The correct dosage rate is dependant upon several parameters, including feed temperature, pH, and chemical analysis and will be specified by your consultant after a detailed survey of your plant. To obtain t [+] Read More...
Note:
Antiscalant 9209 RX  is an aqueous solution of neutralised phosphonic acid. It has been approved for use in potable water applications and does not contribute to assimilable organic carbon (AOC), which can act as source of nutrient for micro-organisms. 
Technical Specifications:

 

Appearance Clear, Yellowish Amber Liquid
Flash point Non-flammable
Solubility in water Soluble in all proportions
Freezing Point -15 Degree

SAFETY INFORMATION:

Gloves and goggles should be worn as a precaution when handling the concentrated solution. (See Material Safety Data Sheets for further information).

Remarks:

SAFETY INFORMATION:

Gloves and goggles should be worn as a precaution when handling the concentrated solution. (See Material Safety Data Sheets for further information).
Antiscalant 9209 RX  is compatible with carbon steel and other commonly used materials of construction. Observe all safety precautions shown in the material safety data sheet, available on request.

ANTISCALANT 9209 RX seawater distillation plants, Compatible with all types of polyamide membrane
ANTISCALANT 9209 RX powerfully Inhibits common scales Calcium carbonate/sulphate - Calcium phosphateBarium/Strontium sulphate - SilicaIron/Manganese

#AntiScalant_ManufacturerSupplier
#Antiscalant_DubaiAbudhabiAjmanFujairah
#Antiscalant_MuscatSoharOman
#Antiscalant_MumbaiChennaiKolkataSuratGandhidhamVizag

RXSOL-51-6005-025 ANTISCALANT and Antifoulant for Reverse Osmosis and Nano Filtration unit.

ANTISCALANT 9209 RX FOR seawater distillation plants manufacturer and supplier in Fujairah, Muscat, Barka, Oman, Dubai, Sharjah, Abudhabi, UAE Middle East, Ajman, Mumbai, Kolkata, Kandla, Visakhapatnam, Chennai Surat, CANADA, Kenya Nairobi, Jinja Uganda

ANTISCALANT 9209 RX Seawater Distillation Plants RXSOL-51-6005-025 is Suitable for Reverse Osmosis (RO) and NanoFiltration (NF) membranes
✓ Effective at LSI up to +2.6
✓ Excellent inhibitor for iron fouling
✓ Excellent silica antiscalant
✓ NSF listed product
✓ Approved for use in drinking water applications (UKDWI)
✓ Compatible with all types of polyamide membrane
✓ Replaces acid addition
✓ Inhibits common scales
- Calcium carbonate/sulphate
 - Calcium phosphate
 - Barium/Strontium sulphate
 - Silica
- Iron/Manganese
ANTISCALANT 9209 RX Seawater Distillation Plants RXSOL-51-6005-025 Inhibits Scale Formation, Prevents Iron Fouling
ANTISCALANT 9209 RX Seawater Distillation Plants
:
Packing Size:
30.00 Kg.Liq
Available Packing Size:
30 Kg Liquid, 55, 250 Kg Liquid
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

ROCCOR NB Corrosion Scale Inhibitor Liquid

Product Description | Product Application | Product Notes| Product DOSE
COOLING WATER CORROSION & SCALE INHIBITOR
Code:
RXSOL-40-4001-025
Other Equivalent Brand

Caretreat 2 Diesel, Coronil 202, Gyrocor RX W.C., DEWT NC, Liquid EWT, Cool water Treat Corrosion Inhibitor, CWT Nclt diesel, Liquid guard 2000, ENGINE JACKET WATER CONDITIONER, Aquafine 103, CWT-NT Chemo, NCT-105 L Norc, Cooling Agent Liquid

Short Description:
Unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants , dispersant and buffer solution of non carbonate.Usefull for use in high or low temperature closed cooling water syste
Generic Name:
Closed Cooling System corrosion inhibitor
Information:

Nitrite borax corrosion inhibitor liquid is one of popular cooling water treatment chemical. This product contains nitrite and borate as major component along with new generation corrosion inhibitor which makes new advance Nitrite borax corrosion inihibitor then others. Many experiment proves that  water of closed cooling system required special treatment to prevent pitting corrosion and scale formation. Special Blend of Nitrite and Borate with watersoftening polymer plays excellent role in cooling system.

Active Matter:
68 - 75
ROCCOR NB Corrosion Scale Inhibitor Liquid
Application:
Prolongs the life of equipment by keeping it scale and corrosion free. Since RXSOL-40-4001-025 is alkaline, it will suppress acid corrosion, which would otherwise result in sever pittings. It improves [+] Read More...
Using Procedure:
Refer to technical datasheet. GENERAL RECOMMENDATION : ( The dosage chart may be used as a guide to adjust treatment to obtain the optimum level.) Nitrite (as PPM NO2) 0  100 [+] Read More...
Note:
Initial dosage for an untreated system is 9 litres of RXSOL-40-4001-025 / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result [+] Read More...
Technical Specifications:

RX MARINE INTERNATIONAL are continiously working in water treatement sector, And developed many unique product to avoid corrosion and scale depositon in cooling water system. Here I wants to keep our experiment results with you.Corrosion inhibitor for closed cooling systems containing molybdate/phosphonate ( RXSOL-40-4018-025 ). Sodium molybdate has the advantage in that the dosing of lower ppm's of molybdate allow for lower conductivity of the circulating water. Sodium molybdate at levels of 50-100 ppm offer the same levels of corrosion inhibition that sodium nitrite at levels of 800+ ppm. By utilizing lower concentrations of sodium molybdate, conductivity is kept at a minimum and thus galvanic corrosion potentials are decreased.

Remarks:

Before testing of Nitrite level, Here is some point and guideline,  what you need to do. : 1 take the following readings; pH, TDS (uS), and nitrite level.and record. 2 add the Chemical your are using. 3. wait for a period of time for the sysem to circulate. hours> 4. Re check the readings. and record. 5 track these readings
for a period of time.

If the TDS and Nitrite drop you have a leak/ unknown makeup. if the TDS stays stable and the nitrite drops you have a biological problem. Bacteria that convert nitrite to nitrate.

Solution ::: Use DI water in place of general water, And also use. Algaecide to control Bacterial growth inside water system ... http://rxmarine.com/Biocide-Algaecide

The closed cooling system uses the water flowing through a heat exchanger to remove heat from the engines. If Continuous flow of cooling water contains ROCCORRX Nb corrosion inhibitor and antifreeze mixture resulting good protect towards metal surface. 

CWT ROCCORRXRX NB Corrosion Scale Inhibitor Liquid is classified marine chemical corrosion inhibitor for engine cooling water systems. ROCCORRX NB Liq effectively protects ferrous and non-ferrous metals of engine cooling system. RXSOL CWT ROCCORRXRX NB Corrosion Scale Inhibitor Liquid is used in diesel engines, compressors, process cooling systems as ROCCOR nb liquid is the suitable and most popular corrosion inhibitor for closed heating or cooling systems of machinery and engine system.

CWT ROCCORRXRX NB Corrosion Scale Inhibitor Liquid  equivalent product is CWT Diessel NB Guard, Liqui dewt, ROCCORRX NB liquid
CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid msds and technical bulletine available here.
CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid is one of classified corrosion inihibitor for cooling water system. Ferrous and Non ferrous metal parts of cooling water system gets corrosion and changes into pitting formation which results in the form of leakage and many more. But presence of balance level of nitrite and borax which is main compenent of CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid, effectively control corrosion on metal surface, This is the reason why uses of ROCCORRX NB liquid is most common in COOLING WATER SYSTEM on the other hand we can say that CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid is the ideal corrosion inhibitor for closed heating or cooling systems, such as diesel engines, compressors, process cooling systems, etc.

Also refer this link http://rxmarine.com/engine-water-treatment-corrosion-inhibitor

CWT RoccorRX NB Corrosion Scale Inhibitor Liquid manufacturer and supplier in Mumbai, turbhe Pawana Navi Mumbai, Panvel, Taloja, Gandhidham, Kandla, Mundra, Jamnagar, Hazira, Surat, Manglore, Chennai Ennore, Visakhapatnam, Gangavaram, Kolkata, Haldia, Paradip Odisha, Fujairah, Dubai, Ajman, Abudhbai, Muscat Oman Barka Sohar, Canada

ROCCOR Nitrite Borax with proprietory mixture is most popular Corrosion Inhibitor for cooling water jacketed system.

How to Protect internal combustion engines, compressors, chiller system and DG sets from Corrosion?

ROCCOR NB Corrosion Inhibitor is a  unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants, dispersant and buffer solution of non carbonate.

ROCCOR NB is specialized such a way which can be use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Also Usefull to Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride.


The stable protective microfilm prevents corrosion caused by electrolytic action and the alkaline nature of this product prevents acid attack.

The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. 

During Circulation of water mainly controlling of 2 factors required : -
 
SCALE CONTROL in closed water cooling systems - Diesel and gas engines releasing high temperature due to that water present in jacket cooling system  increases its tendency to deposit scale. To avoid scale formation water softener like Zeolite  gradual buildup of scale in cylinders and cylinder heads. Where condensate is available, it is preferred for closed system cooling water makeup. Where condensate is not available, zeolite softening should be applied to the makeup water.
 
CORROSION CONTROL An increase in water temperature causes an increase in corrosion. At high temperature  solubility of oxygen in water decreases due to that Corrosion rates increasing inside the system.  This occurs because the lower solubility of oxygen with increasing temperatures in a freely vented system decreases the corrosion rate faster than the rise in temperature increases it. However, in many closed systems, the dissolved oxygen entering the system in the makeup water cannot be freely vented, resulting in the release of oxygen at points of high heat transfer, which may cause severe corrosion. Untreated systems can suffer serious corrosion damage from oxygen pitting, galvanic action, and crevice attack. Closed cooling systems that are shut down periodically are subjected to water temperatures that may vary from ambient to 180°F (82°C) or higher. During shutdown, oxygen can enter the water until its saturation limit is reached. When the system is returned to high-temperature operation, oxygen solubility drops and the released oxygen attacks metal surfaces. 
 
The three most reliable corrosion inhibitors for closed cooling water systems are chromate, molybdate, and nitrite materials. Generally, the chromate or molybdate types have proven to be superior treatments.
ROCCOR NB Corrosion Inhibitor

What is closed cooling system ?

The full closed cooling system is designed to circulate cooling water through the block and exhaust manifold.  water is circulated through water pump to heat exchanger tank and be pumped through many small tubes where it will exchange heat from the water of the circulating system. Then water exits the heat exchanger to go directly into the risers and then exit the boat. The exhaust manifold and riser will be blocked off, so no water will transfer between them. As for the circulating water in the closed cooling system, cool water will enter the engine through the circulating pump and circulate through the engine. The water will heat up in the engine and the warm water will exit at the water outlet on top of the manifold and head to the manifolds. After circulating through the manifolds, the hot water will head to the heat exchanger to exchange the heat it's carrying with the raw water. After the exchange the cool circulating water exits the heat exchanger and returns to circulating pump to begin another loop. 
 

How to Protect internal combustion engines, compressors, chiller system and DG sets from Corrosion?
 
ROCCOR NB Corrosion Inhibitor is a  unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants, dispersant and buffer solution of non carbonate.
 
ROCCOR NB is specialized such a way which can be use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Also Usefull to Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride.
 
 
The stable protective microfilm prevents corrosion caused by electrolytic action and the alkaline nature of this product prevents acid attack.
 
The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. 
 
FIELDS ::: --- Suitable for use in closed water cooling systems, ice melting systems and transformer cooling systems. The product may be used in all kinds of diesel & petrol engines, compressor or heating cooling water circuits.
 
 
 
Where Roccor NB can be used?
 
Prolongs the life of equipment by keeping it scale and corrosion free. Since RXSOL-40-4001-025 is alkaline, it will suppress acid corrosion, which would otherwise result in sever pittings. It improves cooling efficiency by maintaining clean heat transfer surfaces , from Radiators, DG - sets, Closed Cooling and chiller System.
 
FIELDS ::: --- Suitable for use in closed water cooling systems, ice melting systems and transformer cooling systems. The product may be used in all kinds of diesel & petrol engines, compressor or heating cooling water circuits.
 
 
( Used as a corrosion inhibitor for all ferrous and non-ferrous metals found in water systems )
 
 
 
DOSES and Using procedure of ROCCOR NB?
 
 
GENERAL RECOMMENDATION : ( The dosage chart may be used as a guide to adjust treatment to obtain the optimum level.)
 
Nitrite (as PPM NO2) 0 100-200 300-600 700-900 1100-1300   
RXSOL-40-4001-025 / 1000L 8.0 7.3 7-8 5-7  1.5-3.5
NOTE ::: --   If nitrite level becomes 1440-2400 then doses should be ZERO.
 
 
The initial dosage for an untreated system is 8 liters of product per 1000 liters of water. Such a dose will bring nitrite levels over 1200 ppm. Maximum nitrite level is considered to be 2400 ppm. Frequent tests should be carried out in order to maintain pH values within the limit (8.3-10.0), while levels of chloride should be maximum 50 ppm.
 
Initial dosage for an untreated system is 9 litres of RXSOL-40-4001-025 / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine life add RXSOL-40-4001-025 every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval. Specially designed for use in  water systems of internal combustion equipment. pH should be maintained between 8.3 and 10 by the treatment.
 
RXSOL-40-4001-025 will react with sludge and in most cases, facilitate sludge gradual removal. On badly fouled systems with oil or scale, a prior degreasing by using DEGREASER HEAVY DUTY or descaling by using DEGREASER HEAVY DUTY, SCALE REMOVER LIQUID or SCALE REMOVER POWDER is highly recommended.
 
 
• Excellent corrosion inhibitor for cooling water
 
• Minimises metal oxide deposits
 
• Protects ferrous and non-ferrous metals
 
• Compatible with glycol-based antifreeze
 
• Reduces cleaning & maintenance costs
 
• Cost effective, easy to apply and use

ROCCOR NB Corrosion Scale Inhibitor Liquid specialized marine chemical product for Cooling Water treatment. ROCCOR NB Corrosion Scale Inhibitor Liquid supplier in Mumbai, Kandla Mundra, TURBHA MIDC NAVI Mumbai, Hazira SURAT, Visakhapatnam, Gangavaram, Chennai, Ennore, Kolkata, Haldia, Paradip, Kakinada, Fujairah, Ajman, Abudhabi, Sharjah, Dubai, UAE GULF, Ruwi Gala Barka, Muscat Oman, Canada, Nairobi Kenya Sudan, Yemen
ROCCOR NB Corrosion Scale Inhibitor Liquid
ROCCOR NB Corrosion Scale Inhibitor Liquid
ROCCOR NB Corrosion Scale Inhibitor Liquid
:
Packing Size:
25.00 Ltr.
Available Packing Size:
5, 20, 35, 50, 210 Ltr Mail us for Factory sale Discounted price of chemically effective corrosion inhibitor. Which is controlling common ferrous and non-ferrous metals in cooling water jacketed systems. Nitrite-borate based. Liquid and alkaline medium. Operates in a high and low-temperature closed system in internal combustion engines.
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Cool Water Treat

Product Description | Product Application | Product Notes| Product DOSE
Code:
RXSOL-40-4012-020
Other Equivalent Brand

C.W.T. Inhibitor 9-111, COOL WATER TREAT NCL, Coolwater Treat, Cool water treat, Cool Treat, Corrosion Inhibitor for Cooling Water, CoolTreat 25 Ltr

Short Description:
Cool water Treat Corrosion Inhibitor can be used in conjunction with glycols for frost protection. If used in conjunction with glycols, It is recommended to increase the product concentration to 8%.*
Generic Name:
Cooling Water Corrosion Inhibitor
Active Matter:
45-50
Cool Water Treat
Application:
Cool Water Treat  is a highly effective corrosion inhibitor for all common metals in cooling water systems. Testing has shown no detrimental effects on non metallic substances such as seals, glands, p [+] Read More...
Using Procedure:
Cool Water Treat should be dosed to a suitable point in the system. If the expansion tank is used, adequate circulation must be assured. Dosing and Control Initial dosage for an untreated system is 60 li [+] Read More...
Note:
Liquid product, easy to use Environmentally friendly, fully organic product, low toxicity Effective against cavitation and erosion. Superior heat transfer properties Compatible with hoses, ga [+] Read More...
Technical Specifications:

APPEARANCE

Colorless liquid

Density, g/cm3 at 20°C:

1.055

pH

8.2

COMPATIBILITY

 

Metal

All commonly used

Rubber

No known effect

 
Remarks:

Cool Water Treat is specialized corrosion inhibitor for Cooling Water system.

#CorroSionInhibitor_CoolingSystem
#CoolingWaterTreatmentChemicals
#CWTinhbitor_ManufacturerSupplierIndiaUAEoman


Cool Water Treat corrosion inhibitor for cooling water system manufacturer and supplier in Mumbai, Navi Mumbai, Gandhidham, Hazira Surat, Chennai Ennore, Vizag Visakhapatnam, Kolkata Haldia, Buzbuz, Paradip, Fujairah, Dubai, Ajman, Abudhabi, Muscat, Oman, Canada, Nairobi Kenya, Sudan, Yemen


Cool Water Treat
:
Packing Size:
25.00 Ltr.
Available Packing Size:
Cool Water Treat - A corrosion Inhibitor also called a coolant Inhibitor is a specialized corrosion inhibitor for the Cooling Water system to protect all metal-containing systems. Cool Water Treat is available in 20, 25, and 50, 220 Ltrs packing.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

RX MARINE INTERNATIONAL is most popular chemicals source in INDIA, Keeping ready stock at 5 LOCATION which includes Mumbai, Kandla - Gandhidham, Vizag - Visakhapatnam, Ennore - Chennai, Kolkata more then 3000 types of chemicals. Please click here to get PRODUCT Categories details http://rxmarine.com/Products

 

Mail Us for any PRODUCT related information and purchase inquiry : mail@rxmarine.com ( This mail is for customer / Buyer only ) And if you wants to add your hand as a supplier, And if you have volume manufacturing capacity of chemicals, pl. drop your mail at rxmarine@gmail.com ( This mail is for supplier only )

 

 

Syndicate content