Coconut Shell Based Activated Carbon

Product Description | Product Application | Product Notes| Product DOSE
Coconut Shell Based Activated Carbon manufacturer and supplier
Code:
RXSOL-32-3107-030
Other Equivalent Brand

550812

Short Description:
Activated Carbon is a very active product with a high proportion of medium and large pores. It is recommended for the adsorption of large quantities of high molecular weight substances.
Generic Name:
Gold Purifier Carbon
Active Matter:
100
Coconut Shell Based Activated Carbon
Application:
Activated carbon is useful in drinking water treatment because it acts as an adsorbent , and can effectively remove particles and  organics from water. These organics are of great concern in water tr [+] Read More...
Using Procedure:
An amorphous from of carbon characterized by high adsorptivity for many gases, vapors, and collodial solids. Used for water and air purification, solvent recovery, waste treatment, removal of sulfur oxide from stack gases and "clean'' rooms as deodorant, and for air conditioning.
Note:
Coconut Shell Based Activated Carbon Granual most commonly used for Filteration and decolorization of fruit juice, Also helpful for clarification date syrup.
Technical Specifications:

 

Physical

Appearance: Dark grey/black Granual / Powder
Specific Gravity: .22-.32
Pour Point: 2150ºC
Flash Point: Not flammable

Chemical

Type: Charcoal
Solubility: Negligible (water, oil)
pH: 4.0-6.0
Microtox: Not applicable

Remarks:

RXSOL Group of industries popular and certified largest manufacturer & exporter of Superior and Quality activated carbon in India. Activated Carbon Helpfull to provide Decolourisation and Purifications solutions, Air Purification, Water Filtration etc.
WOOD BASED POWDERED ACTIVATED CARBON
WOOD BASED GRANULAR ACTIVATED CARBON
COCONUT SHELL BASED GRANULAR ACTIVATED CARBON
COAL BASED GRANULAR & POWDER ACTIVATED CARBON
PELLETS ACTIVATED CARBON
 
What Is Activated Carbon
Activated carbons are manufactured from coconut shell, peat, hard and soft wood, lignite coal, bituminous coal, olive pits and various specialty materials.
 
Activated carbons are manufactured from coconut shell, peat, hard and soft wood, lignite coal, bituminous coal, olive pits and various specialty materials. Manufactured by chemical or high temperature steam activation, this highly porous adsorptive medium has a complex structure that is composed primarily of carbon atoms. Its network of pores within a rigid carbon skeleton consists of disordered layers of carbon atoms which are linked together by random chemical or carbon bonds.
 
 
 
APPLICATION AREA
 
Air & Gas Treatment
Water Treatment
Pharmaceuticals Industry
Gold Recovery
Food & Beverages
Automotive Industry
Mercury Removal
Biogas Industry
Protective Equipments
Petrochemicals Catalyst
Cigarette Filters
Soil Remediation

Coconut Shell Based Activated Carbon manufacturer, supplier and exporter in Mumbai, Kandla - Gandhidham, Chennai, Visakhapatnam, Kolkata, Dubai, Fujairah, Sharjah, Abu Dhabi, Oman - Muscat.

Coconut Shell Based Activated Carbon
Coconut Shell Based Activated Carbon
Coconut Shell Based Activated Carbon
:
Packing Size:
25.00 Kg Granules
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

SODIUM HYDROXIDE ANHYDROUS

Product Description | Product Application | Product Notes| Product DOSE
Code:
RXSOL-40-1618-050
Other Equivalent Brand
Short Description:
SODIUM HYDROXIDE ANHYDROUS
SODIUM HYDROXIDE ANHYDROUS
Application:
Using Procedure:
Note:
Technical Specifications:
SODIUM HYDROXIDE ANHYDROUS
:
Packing Size:
50.00 Kg.PWD
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Zinc Phosphide Eighty Precent

Product Description | Product Application | Product Notes| Product DOSE
Code:
RXSOL-19-3713-025
Other Equivalent Brand
Short Description:
Rodenticide used in agricultural and industrial situation.
Zinc Phosphide Eighty Precent
Application:
Using Procedure:
Note:
Technical Specifications:
Zinc Phosphide Eighty Precent
:
Packing Size:
25.00 Kg
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Defoamer Silicone Based

Product Description | Product Application | Product Notes| Product DOSE
RXSOL-16-2066-200 is antifoam emulsion and its more concentrated antifoam emulsion. It has excellent candidates for controlling foam in amine and glycol dehydration units. This is suitable products f [+] Read More...
Code:
RXSOL-40-2066-200
Other Equivalent Brand

Defoamer, ANTISPUMIN DS ANTI FOAM, Antifoam 210 Ltr

Short Description:
RXSOL-16-2066-200 is antifoam emulsion and its more concentrated antifoam emulsion. It has excellent candidates for controlling foam in amine and glycol dehydration units. This is suitable products for gas plants and have excellent stability in the presence
Generic Name:
Silicon Based Antifoam Emulsion
Active Matter:
81-90
Defoamer Silicone Based
Application:
This antifoam compound are targeted for gas recovery plants, where natural gas must be washed, or scrubbed, before distribution, and for liquefied natural gas (LNG) plants that must achieve high gas [+] Read More...
Using Procedure:
General-purpose antifoams have a wide range of applicability, but not all of them are suitable for use in the treatment of gas. Some foam control agents can aggravate the problem. Foam control in gas scrubb [+] Read More...
Note:
Key Features and Benefits Quick foam knockdown - particularly useful when foam suddenly builds up in the absorber and rapid control is needed. Excellent antifoarn stability and durability - over a [+] Read More...
Technical Specifications:

 

Emulsion: Silicone Antifoam Emulsion RXSOL-16-2066-210
Chemical Nature Emulsion of a silicone antifoam compound
Appearance White, homogeneous, slightly viscous liquid

Viscosity at 25°C, cSt
600
Active Ingredients, % 10
Specific Gravity at 25°/25°C 1
pH 7
Emulsion Type Non-ionic
Suitable Diluents Water only
 
Remarks:

#Defoamer_Muscat
#defoamer_dubai
#defoamer_manufacturer
#Defoamer_supplier
#Silicone_Defoamer


Antifoam Defoamer manufacturer, exporter and supplier in India Mumbai, Kolkata, Chennai, Vizag, Gandhidham, Surat, UAE Middle East Dubai, Sharjah, Ajman, ABudhabi, Iraq, Kuwait, Oman Muscat Barka Ruwi, Canada


Defoamer Silicone Based
:
Packing Size:
210.00 Ltr.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

ANTISCALANT 9209 RX Seawater Distillation Plants

Product Description | Product Application | Product Notes| Product DOSE
Antiscalant 9209 RX is specially designed to control the development of scale in seawater distillation plants. It is based on a synergistic blend of phosphonates which are found to be more effective t [+] Read More...
Code:
RXSOL-51-6005-025
Other Equivalent Brand

Hydrex 9209, Metito M 915, Genesys LF

Short Description:
Antiscalant for Water Distillation Units , specially designed to control the development of scale in seawater distillation plants.
Generic Name:
Broad Spectrum Antiscalant and Antifoulant Liquid
Active Matter:
94-98
ANTISCALANT 9209 RX Seawater Distillation Plants
Application:
PREVENTS IRON FOULING and SILICA ANTISCALANT properties. Convenient liquid formulation for automatic dosing using suitable dosing equipment. Prevents formation of hard scale in seawater disti [+] Read More...
Using Procedure:
The correct dosage rate is dependant upon several parameters, including feed temperature, pH, and chemical analysis and will be specified by your consultant after a detailed survey of your plant. To obtain t [+] Read More...
Note:
Antiscalant 9209 RX  is an aqueous solution of neutralised phosphonic acid. It has been approved for use in potable water applications and does not contribute to assimilable organic carbon (AOC), which can act as source of nutrient for micro-organisms. 
Technical Specifications:

 

Appearance Clear, Yellowish Amber Liquid
Flash point Non-flammable
Solubility in water Soluble in all proportions
Freezing Point -15 Degree

SAFETY INFORMATION:

Gloves and goggles should be worn as a precaution when handling the concentrated solution. (See Material Safety Data Sheets for further information).

Remarks:

SAFETY INFORMATION:

Gloves and goggles should be worn as a precaution when handling the concentrated solution. (See Material Safety Data Sheets for further information).
Antiscalant 9209 RX  is compatible with carbon steel and other commonly used materials of construction. Observe all safety precautions shown in the material safety data sheet, available on request.

ANTISCALANT 9209 RX seawater distillation plants, Compatible with all types of polyamide membrane
ANTISCALANT 9209 RX powerfully Inhibits common scales Calcium carbonate/sulphate - Calcium phosphateBarium/Strontium sulphate - SilicaIron/Manganese

#AntiScalant_ManufacturerSupplier
#Antiscalant_DubaiAbudhabiAjmanFujairah
#Antiscalant_MuscatSoharOman
#Antiscalant_MumbaiChennaiKolkataSuratGandhidhamVizag

RXSOL-51-6005-025 ANTISCALANT and Antifoulant for Reverse Osmosis and Nano Filtration unit.

ANTISCALANT 9209 RX FOR seawater distillation plants manufacturer and supplier in Fujairah, Muscat, Barka, Oman, Dubai, Sharjah, Abudhabi, UAE Middle East, Ajman, Mumbai, Kolkata, Kandla, Visakhapatnam, Chennai Surat, CANADA, Kenya Nairobi, Jinja Uganda

ANTISCALANT 9209 RX Seawater Distillation Plants RXSOL-51-6005-025 is Suitable for Reverse Osmosis (RO) and NanoFiltration (NF) membranes
✓ Effective at LSI up to +2.6
✓ Excellent inhibitor for iron fouling
✓ Excellent silica antiscalant
✓ NSF listed product
✓ Approved for use in drinking water applications (UKDWI)
✓ Compatible with all types of polyamide membrane
✓ Replaces acid addition
✓ Inhibits common scales
- Calcium carbonate/sulphate
 - Calcium phosphate
 - Barium/Strontium sulphate
 - Silica
- Iron/Manganese
ANTISCALANT 9209 RX Seawater Distillation Plants RXSOL-51-6005-025 Inhibits Scale Formation, Prevents Iron Fouling
ANTISCALANT 9209 RX Seawater Distillation Plants
:
Packing Size:
30.00 Kg.Liq
Available Packing Size:
30 Kg Liquid, 55, 250 Kg Liquid
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Drilling Detergent RXSOL ORG DD 1000 Ltr

Product Description | Product Application | Product Notes| Product DOSE
Code:
RXSOL-81-8139-100
Other Equivalent Brand
Short Description:
It is designed to reduce the surface tension of all water-base mud systems and reduce the sticking tendency of water-sensitive shale cuttings.
Drilling Detergent RXSOL ORG DD 1000 Ltr
Application:
Using Procedure:
Note:
Technical Specifications:
Drilling Detergent RXSOL ORG DD 1000 Ltr
:
Packing Size:
1000.00 Ltr.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

ROCCOR NB Corrosion Scale Inhibitor Liquid

Product Description | Product Application | Product Notes| Product DOSE
COOLING WATER CORROSION & SCALE INHIBITOR
Code:
RXSOL-40-4001-025
Other Equivalent Brand

Caretreat 2 Diesel, Coronil 202, Gyrocor RX W.C., DEWT NC, Liquid EWT, Cool water Treat Corrosion Inhibitor, CWT Nclt diesel, Liquid guard 2000, ENGINE JACKET WATER CONDITIONER, Aquafine 103, CWT-NT Chemo, NCT-105 L Norc, Cooling Agent Liquid

Short Description:
Unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants , dispersant and buffer solution of non carbonate.Usefull for use in high or low temperature closed cooling water syste
Generic Name:
Closed Cooling System corrosion inhibitor
Information:

Nitrite borax corrosion inhibitor liquid is one of popular cooling water treatment chemical. This product contains nitrite and borate as major component along with new generation corrosion inhibitor which makes new advance Nitrite borax corrosion inihibitor then others. Many experiment proves that  water of closed cooling system required special treatment to prevent pitting corrosion and scale formation. Special Blend of Nitrite and Borate with watersoftening polymer plays excellent role in cooling system.

Active Matter:
68 - 75
ROCCOR NB Corrosion Scale Inhibitor Liquid
Application:
Prolongs the life of equipment by keeping it scale and corrosion free. Since RXSOL-40-4001-025 is alkaline, it will suppress acid corrosion, which would otherwise result in sever pittings. It improves [+] Read More...
Using Procedure:
Refer to technical datasheet. GENERAL RECOMMENDATION : ( The dosage chart may be used as a guide to adjust treatment to obtain the optimum level.) Nitrite (as PPM NO2) 0  100 [+] Read More...
Note:
Initial dosage for an untreated system is 9 litres of RXSOL-40-4001-025 / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result [+] Read More...
Technical Specifications:

RX MARINE INTERNATIONAL are continiously working in water treatement sector, And developed many unique product to avoid corrosion and scale depositon in cooling water system. Here I wants to keep our experiment results with you.Corrosion inhibitor for closed cooling systems containing molybdate/phosphonate ( RXSOL-40-4018-025 ). Sodium molybdate has the advantage in that the dosing of lower ppm's of molybdate allow for lower conductivity of the circulating water. Sodium molybdate at levels of 50-100 ppm offer the same levels of corrosion inhibition that sodium nitrite at levels of 800+ ppm. By utilizing lower concentrations of sodium molybdate, conductivity is kept at a minimum and thus galvanic corrosion potentials are decreased.

Remarks:

Before testing of Nitrite level, Here is some point and guideline,  what you need to do. : 1 take the following readings; pH, TDS (uS), and nitrite level.and record. 2 add the Chemical your are using. 3. wait for a period of time for the sysem to circulate. hours> 4. Re check the readings. and record. 5 track these readings
for a period of time.

If the TDS and Nitrite drop you have a leak/ unknown makeup. if the TDS stays stable and the nitrite drops you have a biological problem. Bacteria that convert nitrite to nitrate.

Solution ::: Use DI water in place of general water, And also use. Algaecide to control Bacterial growth inside water system ... http://rxmarine.com/Biocide-Algaecide

The closed cooling system uses the water flowing through a heat exchanger to remove heat from the engines. If Continuous flow of cooling water contains ROCCORRX Nb corrosion inhibitor and antifreeze mixture resulting good protect towards metal surface. 

CWT ROCCORRXRX NB Corrosion Scale Inhibitor Liquid is classified marine chemical corrosion inhibitor for engine cooling water systems. ROCCORRX NB Liq effectively protects ferrous and non-ferrous metals of engine cooling system. RXSOL CWT ROCCORRXRX NB Corrosion Scale Inhibitor Liquid is used in diesel engines, compressors, process cooling systems as ROCCOR nb liquid is the suitable and most popular corrosion inhibitor for closed heating or cooling systems of machinery and engine system.

CWT ROCCORRXRX NB Corrosion Scale Inhibitor Liquid  equivalent product is CWT Diessel NB Guard, Liqui dewt, ROCCORRX NB liquid
CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid msds and technical bulletine available here.
CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid is one of classified corrosion inihibitor for cooling water system. Ferrous and Non ferrous metal parts of cooling water system gets corrosion and changes into pitting formation which results in the form of leakage and many more. But presence of balance level of nitrite and borax which is main compenent of CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid, effectively control corrosion on metal surface, This is the reason why uses of ROCCORRX NB liquid is most common in COOLING WATER SYSTEM on the other hand we can say that CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid is the ideal corrosion inhibitor for closed heating or cooling systems, such as diesel engines, compressors, process cooling systems, etc.

Also refer this link http://rxmarine.com/engine-water-treatment-corrosion-inhibitor

CWT RoccorRX NB Corrosion Scale Inhibitor Liquid manufacturer and supplier in Mumbai, turbhe Pawana Navi Mumbai, Panvel, Taloja, Gandhidham, Kandla, Mundra, Jamnagar, Hazira, Surat, Manglore, Chennai Ennore, Visakhapatnam, Gangavaram, Kolkata, Haldia, Paradip Odisha, Fujairah, Dubai, Ajman, Abudhbai, Muscat Oman Barka Sohar, Canada

ROCCOR Nitrite Borax with proprietory mixture is most popular Corrosion Inhibitor for cooling water jacketed system.

How to Protect internal combustion engines, compressors, chiller system and DG sets from Corrosion?

ROCCOR NB Corrosion Inhibitor is a  unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants, dispersant and buffer solution of non carbonate.

ROCCOR NB is specialized such a way which can be use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Also Usefull to Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride.


The stable protective microfilm prevents corrosion caused by electrolytic action and the alkaline nature of this product prevents acid attack.

The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. 

During Circulation of water mainly controlling of 2 factors required : -
 
SCALE CONTROL in closed water cooling systems - Diesel and gas engines releasing high temperature due to that water present in jacket cooling system  increases its tendency to deposit scale. To avoid scale formation water softener like Zeolite  gradual buildup of scale in cylinders and cylinder heads. Where condensate is available, it is preferred for closed system cooling water makeup. Where condensate is not available, zeolite softening should be applied to the makeup water.
 
CORROSION CONTROL An increase in water temperature causes an increase in corrosion. At high temperature  solubility of oxygen in water decreases due to that Corrosion rates increasing inside the system.  This occurs because the lower solubility of oxygen with increasing temperatures in a freely vented system decreases the corrosion rate faster than the rise in temperature increases it. However, in many closed systems, the dissolved oxygen entering the system in the makeup water cannot be freely vented, resulting in the release of oxygen at points of high heat transfer, which may cause severe corrosion. Untreated systems can suffer serious corrosion damage from oxygen pitting, galvanic action, and crevice attack. Closed cooling systems that are shut down periodically are subjected to water temperatures that may vary from ambient to 180°F (82°C) or higher. During shutdown, oxygen can enter the water until its saturation limit is reached. When the system is returned to high-temperature operation, oxygen solubility drops and the released oxygen attacks metal surfaces. 
 
The three most reliable corrosion inhibitors for closed cooling water systems are chromate, molybdate, and nitrite materials. Generally, the chromate or molybdate types have proven to be superior treatments.
ROCCOR NB Corrosion Inhibitor

What is closed cooling system ?

The full closed cooling system is designed to circulate cooling water through the block and exhaust manifold.  water is circulated through water pump to heat exchanger tank and be pumped through many small tubes where it will exchange heat from the water of the circulating system. Then water exits the heat exchanger to go directly into the risers and then exit the boat. The exhaust manifold and riser will be blocked off, so no water will transfer between them. As for the circulating water in the closed cooling system, cool water will enter the engine through the circulating pump and circulate through the engine. The water will heat up in the engine and the warm water will exit at the water outlet on top of the manifold and head to the manifolds. After circulating through the manifolds, the hot water will head to the heat exchanger to exchange the heat it's carrying with the raw water. After the exchange the cool circulating water exits the heat exchanger and returns to circulating pump to begin another loop. 
 

How to Protect internal combustion engines, compressors, chiller system and DG sets from Corrosion?
 
ROCCOR NB Corrosion Inhibitor is a  unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants, dispersant and buffer solution of non carbonate.
 
ROCCOR NB is specialized such a way which can be use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Also Usefull to Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride.
 
 
The stable protective microfilm prevents corrosion caused by electrolytic action and the alkaline nature of this product prevents acid attack.
 
The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. 
 
FIELDS ::: --- Suitable for use in closed water cooling systems, ice melting systems and transformer cooling systems. The product may be used in all kinds of diesel & petrol engines, compressor or heating cooling water circuits.
 
 
 
Where Roccor NB can be used?
 
Prolongs the life of equipment by keeping it scale and corrosion free. Since RXSOL-40-4001-025 is alkaline, it will suppress acid corrosion, which would otherwise result in sever pittings. It improves cooling efficiency by maintaining clean heat transfer surfaces , from Radiators, DG - sets, Closed Cooling and chiller System.
 
FIELDS ::: --- Suitable for use in closed water cooling systems, ice melting systems and transformer cooling systems. The product may be used in all kinds of diesel & petrol engines, compressor or heating cooling water circuits.
 
 
( Used as a corrosion inhibitor for all ferrous and non-ferrous metals found in water systems )
 
 
 
DOSES and Using procedure of ROCCOR NB?
 
 
GENERAL RECOMMENDATION : ( The dosage chart may be used as a guide to adjust treatment to obtain the optimum level.)
 
Nitrite (as PPM NO2) 0 100-200 300-600 700-900 1100-1300   
RXSOL-40-4001-025 / 1000L 8.0 7.3 7-8 5-7  1.5-3.5
NOTE ::: --   If nitrite level becomes 1440-2400 then doses should be ZERO.
 
 
The initial dosage for an untreated system is 8 liters of product per 1000 liters of water. Such a dose will bring nitrite levels over 1200 ppm. Maximum nitrite level is considered to be 2400 ppm. Frequent tests should be carried out in order to maintain pH values within the limit (8.3-10.0), while levels of chloride should be maximum 50 ppm.
 
Initial dosage for an untreated system is 9 litres of RXSOL-40-4001-025 / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine life add RXSOL-40-4001-025 every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval. Specially designed for use in  water systems of internal combustion equipment. pH should be maintained between 8.3 and 10 by the treatment.
 
RXSOL-40-4001-025 will react with sludge and in most cases, facilitate sludge gradual removal. On badly fouled systems with oil or scale, a prior degreasing by using DEGREASER HEAVY DUTY or descaling by using DEGREASER HEAVY DUTY, SCALE REMOVER LIQUID or SCALE REMOVER POWDER is highly recommended.
 
 
• Excellent corrosion inhibitor for cooling water
 
• Minimises metal oxide deposits
 
• Protects ferrous and non-ferrous metals
 
• Compatible with glycol-based antifreeze
 
• Reduces cleaning & maintenance costs
 
• Cost effective, easy to apply and use

ROCCOR NB Corrosion Scale Inhibitor Liquid specialized marine chemical product for Cooling Water treatment. ROCCOR NB Corrosion Scale Inhibitor Liquid supplier in Mumbai, Kandla Mundra, TURBHA MIDC NAVI Mumbai, Hazira SURAT, Visakhapatnam, Gangavaram, Chennai, Ennore, Kolkata, Haldia, Paradip, Kakinada, Fujairah, Ajman, Abudhabi, Sharjah, Dubai, UAE GULF, Ruwi Gala Barka, Muscat Oman, Canada, Nairobi Kenya Sudan, Yemen
ROCCOR NB Corrosion Scale Inhibitor Liquid
ROCCOR NB Corrosion Scale Inhibitor Liquid
ROCCOR NB Corrosion Scale Inhibitor Liquid
:
Packing Size:
25.00 Ltr.
Available Packing Size:
5, 20, 35, 50, 210 Ltr Mail us for Factory sale Discounted price of chemically effective corrosion inhibitor. Which is controlling common ferrous and non-ferrous metals in cooling water jacketed systems. Nitrite-borate based. Liquid and alkaline medium. Operates in a high and low-temperature closed system in internal combustion engines.
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Sodium Thiosulphate Solution

Product Description | Product Application | Product Notes| Product DOSE
Code:
RXSOL-40-2031-210
Other Equivalent Brand

Chlorine control, Declor-it, Disodium thiosulfate, S-hydril, Sodium hyposulfite, Sodium oxide sulfide, Antichlor, Sodothiol, Sulfothiorine, Ametox, Sodium Thiosulfate Neutralizer for TRO ALPHA 50 liquid solution, Sodium Thiosulfate Pentahydrate Solution 250 Kg Liquid

Short Description:
Sodium Thiosulfate used as a water Dechlorinator also used in Pond Aquarium . This product also used as a Photography as a fixing agent hypo to dissolve unchanged silver salts from exposed negatives.
Generic Name:
Disodium thiosulfate
Did you Know?

 How to Remove Chlorine Lavel in Water?

Sodium Thiosulphate Solution
Application:
Dechlorination in municipal, pulp & paper, power, and textile water treatment plants, Oxygen scavenger – oil well drilling process  Mining industries Aluminum cation reaction Industrial production [+] Read More...
Using Procedure:
Process for DE CHLORINATION :::  Dissolve the 500 grams of Sodium Thiosulfate in a large pitcher of lukewarm tap water. Stir until all the crystals are dissolved. Then transfer the solution with a funnel [+] Read More...
Note:
Analytical chemistry Sodium thiosulfate is also used in analytical chemistry. It can, when heated with a sample containing aluminum cation, produce a white precipitation: 2 Al3+ + 3 S2O32− + 3 H2O →3 S [+] Read More...
Technical Specifications:
IUPAC name :Sodium thiosulfate

Other names:Sodium hyposulfite, Hyposulphite of soda

 Identifiers CAS number : 7772-98-7 Y, 10102-17-7 : (pentahydrate)

UNII :L0IYT1O31N Y

ChEMBL CHEMBL : 1201157 N

RTECS number :XN6476000

Molecular Formula

Na2S2O3.5H2O

Molar Mass

158.11 g/mol

Appearance

Clear Liq

Odor

Odorless

Density

1.667 g/cm3

Melting Point

48.3 °C (pentahydrate)

Boiling Point

100 °C (pentahydrate, - 5H2O decomp)

Solubility in Water

76.4 g/100 g H20(20 °C)

 

IUPAC name :Sodium thiosulfate
Other names:Sodium hyposulfite ,Hyposulphite of soda

 Identifiers

CAS number : 7772-98-7 Y,

10102-17-7 : (pentahydrate)

PubChem: 24477

ChemSpider :22885 Y

UNII :L0IYT1O31N Y

ChEMBL CHEMBL : 1201157 N

RTECS number :XN6476000

Remarks:

Keep away from heat as the potential for release of sulfur dioxide fumes exists. Liquid sodium thiosulfate has very low toxicity but routine safety precautions should be practiced. Rubber gloves, safety goggles and protective clothing is recommended. 

Sodium Thiosulfate, wt%30 +/- 2%
Sulfite, wt%1.5 max.
pH 7.0 – 9.0
Physical Properties: 
Specific Gravity @ 25o C 1.252 – 1.34
Density, lbs/gal @ 25o C 10.4 – 11.2

Other Valuable Products...
Sodium Thiosulphate Pentahydrate - Sugar Crystals
Sodium Thiosulphate Pentahydrate – P Crystals
Sodium Thiosulphate Anhydrous
Sodium Acetate Trihydrate
Sodium Acetate Anhydrous
Sodium Metabisulphite
Sodium Bisulphite
Sodium Sulphate Anhydrous
Sodium Sulphite Anhydrous
Ammonium Chloride - Extra Pure
Ammonium Sulphate - Extra Pure
Magnesium Sulphate Heptahydrate - Extra Pure
Mono Sodium Phosphate - Pure
Di Sodium Phosphate Anhydrous - Pure
Tri Sodium Phosphate Dodecahydrate
Sodium Hexa Meta Phosphate

RXSOL is most popular Manufacturer supplier and Stockist for BWTS Ballast Water Treatment chemicals etc. in India United Arab Emirates Oman.

RXSOL Stockist supplier for Neutralizer- Sodium Thiosulfate solid & liquid, Sodium Bicarbonate, Descaling liquid etc TYPE in your URL www.rxmarine.com/Products

 

#SodiumThiosulfatePentahydrate_IndiaUAEoman
#SodiumThiosulfate_supplier


Sodium Thiosulphate Solution Dechlorination Liquid manufacturer and supplier in Mumbai, Kandla, Kolkata Haldia, Chennai, Visakhapatnam, Hazira Surat, Paradip Ennore, JNPT, Ruwi Barka, Ghala, Muscat Oman, Fujairah, Dubai, Sharjah, Ajman, Abudhabi, Nairobi, Kenya, Canada, Sudan, Yemen

Our Other Valuable Ballast Water Tank Cleaning and Treatment Chemicals...

Neutralizer – Sodium Thiosulfate Pentahydrate (Solid and Liquid Form)
Cleaning Agent – Citric Acid Anhydrous (Solid and Liquid Form)
Sodium Bicarbonate
Sodium Chloride
Purified Water
Sodium Thiosulphate Solution
:
Packing Size:
250.00 Kg.Liq
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

Cool Water Treat

Product Description | Product Application | Product Notes| Product DOSE
Code:
RXSOL-40-4012-020
Other Equivalent Brand

C.W.T. Inhibitor 9-111, COOL WATER TREAT NCL, Coolwater Treat, Cool water treat, Cool Treat, Corrosion Inhibitor for Cooling Water, CoolTreat 25 Ltr

Short Description:
Cool water Treat Corrosion Inhibitor can be used in conjunction with glycols for frost protection. If used in conjunction with glycols, It is recommended to increase the product concentration to 8%.*
Generic Name:
Cooling Water Corrosion Inhibitor
Active Matter:
45-50
Cool Water Treat
Application:
Cool Water Treat  is a highly effective corrosion inhibitor for all common metals in cooling water systems. Testing has shown no detrimental effects on non metallic substances such as seals, glands, p [+] Read More...
Using Procedure:
Cool Water Treat should be dosed to a suitable point in the system. If the expansion tank is used, adequate circulation must be assured. Dosing and Control Initial dosage for an untreated system is 60 li [+] Read More...
Note:
Liquid product, easy to use Environmentally friendly, fully organic product, low toxicity Effective against cavitation and erosion. Superior heat transfer properties Compatible with hoses, ga [+] Read More...
Technical Specifications:

APPEARANCE

Colorless liquid

Density, g/cm3 at 20°C:

1.055

pH

8.2

COMPATIBILITY

 

Metal

All commonly used

Rubber

No known effect

 
Remarks:

Cool Water Treat is specialized corrosion inhibitor for Cooling Water system.

#CorroSionInhibitor_CoolingSystem
#CoolingWaterTreatmentChemicals
#CWTinhbitor_ManufacturerSupplierIndiaUAEoman


Cool Water Treat corrosion inhibitor for cooling water system manufacturer and supplier in Mumbai, Navi Mumbai, Gandhidham, Hazira Surat, Chennai Ennore, Vizag Visakhapatnam, Kolkata Haldia, Buzbuz, Paradip, Fujairah, Dubai, Ajman, Abudhabi, Muscat, Oman, Canada, Nairobi Kenya, Sudan, Yemen


Cool Water Treat
:
Packing Size:
25.00 Ltr.
Available Packing Size:
Cool Water Treat - A corrosion Inhibitor also called a coolant Inhibitor is a specialized corrosion inhibitor for the Cooling Water system to protect all metal-containing systems. Cool Water Treat is available in 20, 25, and 50, 220 Ltrs packing.
Article News:
,
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

RX MARINE INTERNATIONAL is most popular chemicals source in INDIA, Keeping ready stock at 5 LOCATION which includes Mumbai, Kandla - Gandhidham, Vizag - Visakhapatnam, Ennore - Chennai, Kolkata more then 3000 types of chemicals. Please click here to get PRODUCT Categories details http://rxmarine.com/Products

 

Mail Us for any PRODUCT related information and purchase inquiry : mail@rxmarine.com ( This mail is for customer / Buyer only ) And if you wants to add your hand as a supplier, And if you have volume manufacturing capacity of chemicals, pl. drop your mail at rxmarine@gmail.com ( This mail is for supplier only )

 

 