Skip to main content
Email :rxmarinechemical@gmail.com
Contact: 91 08069976670,
91 08069976671 , 91 08069976672

Air Cooler Cleaning Chemical LT

Air Cooler Cleaning Chemical LT
SKU
RXSOL-16-1049-025
Supply Location::
Locations

MAINTENANCE CHEMICAL ACC Cleaner chemicals Air Cooler Cleaning Chemical manufacturer, exporter, and supplier in Nairobi Kenya Africa, Chennai Tamilnadu, Visakhapatnam Andhra Pradesh, Kolkata Westbengal, Gandhidham Kandla Surat Gujrat, Fujairah Dubai Sharjah Abudhabi, Ajman, UAE Middle East Gulf, Muscat Oman Sohar Barka, Canada


RXMARINE CHEMICAL TAG::

Cleaner for Air Coolers and Turbo

RXSOL-16-1049-025  is a concentrate solvent emulsion cleaner for cleaning of Air coolers, Scavenging air systems and turbochargers of diesel engine.

Remarks

Note

Characteristics

  • Formulated to remove oil,grease & carbon deposits from air coolers & scavenging system
  • Efficient and economical.
  • May be used for in-service cleaning.
  • Renders surfaces oil-repellent.
  • Maintains and stabilizes air cooler efficiency at maximum.
  • Saves time, maintenance costs and avoids risks of damage when dismantling.
  • Leaves no residue and has no harmful effect on engine.
  • Product in water solution is non-flammable, non-explosive and has no flash point.
  • Can be used for light carbon removal from machinery parts

        **Read the Material Safety Data Sheet before using this product**


PROCEDURE OF USE :
In-service cleaning–RXSOL-16-1049-025 is  passes through the air trunking upstream of the charge aircooler, followed by a clean water rinse.For cleaning of air coolers, it is necessary to use correctly  installed  dosing  and  injection system.

DOSE :
3 to 5 litres of cleaning solution per square meter or as table below:

Engine HP. Solution of 10 to 25% RXSOL-16-1049-025
6,000 to 12,000 2 to 3 litre
12,000 to 24,000 4 to 5 litre
24,000 or  more 6 litre

NOTE :
For cleaning of Air cooler and Air side of  turbochargers, a  solution  of  5 - 25% RXSOL-16-0009-ACC in fresh  water is recommended. Inject the solution for 10-15 minutes, then similar quantity of fresh water injected to rinse off emulsified deposits.

Hand spray Cleaning:-
By Hand spray,apply concentrate RXSOL-16-1049-025 all over the cooler coils. for good emulsification & penetration. Allow the RXSOL-16-1049-025 for a minimum of 1 hour,then use a high pressu ure  water to wash  off  the  loosened deposits. During process  always  keep drain valve  open. After satisfactory cleaning, and flushing through with fresh water, close air cooler drains.Note that during this process the engine must be stopped.

Soak method :
Machine parts with stubborn carbon deposits to be cleaned is dipped into conc.Soln.of ACC then   allow deposits to. Be broken down and loosened before removal, then rinse .

Copyright © 2021 Powered By RXMARINE - All Rights Reserved