Skip to main content
Email :rxmarinechemical@gmail.com
Contact: 91 08069976670,
91 08069976671 , 91 08069976672

Boiler Treatment Chemicals manufacturers in INDIA, UAE, OMAN

Boiler House Essentials

Protect Your Boiler. Save Fuel. Reduce Downtime.

Our key boiler chemicals: oxygen scavengers, scale & corrosion inhibitors, alkalinity control, condensate protectants, antifoam, and cleaners—designed for marine, industrial, and HVAC boilers.

                                                                Corrosion Scale Inhibitor Boiler Treatment

 

Key Products

Click a product to request a data sheet & pricing.

Oxygen Scavenger Boiler Oxy Control

SKU:RXSOL-42-1524-030

A powerful oxygen scavenger for low and medium pressure steam boilers and also a neutraliser for removing chlorine and other biocides to protect sensitive systems.

Know More

OxyShield Plus Oxygen Scavenger

SKU:RXSOL-42-5029-200

Extended condensate protection, enhanced passive film formation, and overall system efficiency.
 

Know More

One Shot Universal Liquitreat 100

SKU:RXSOL-50-5001-025

One SHOT treatment to control the formation of rust and scale in boilers. Contains alkaline compounds, scale and corrosion inhibitors, oxygen scavengers and sludge conditioners.

Know More

ADJUNCT Hardness Control

SKU:RXSOL-25-5006-025

A white dry powder Boiler Water Treatment product used for the reduction of hardness in boilers. Hardness Control is highly soluble in water and It will precipitate calcium hardness as a non-adherent sludge.
 

Know More

Alkalinity Builder pH Booster

SKU:RXSOL-40-5024-025

A high-performance alkaline liquid chemical designed to elevate and stabilize the pH of boiler feed water and condensate systems. It helps in preventing corrosion caused by acidic conditions within the boiler and associated pipelines.
 

Know More

Corrosion Scale Inhibitor Boiler

SKU:RXSOL-42-4029-025

Single treatment for corrosion and scale prevention. The advanced polymer blend promotes the transport of calcium, magnesium, iron, phosphate, and silica through the boiler system, preventing the formation of stubborn deposits.

Know More

Defoamer for BOILER

SKU:RXSOL-42-8127-025

Effective at low dosage. Immediate foam knock-down. Compatible with Oxygen Scavenger, Alkalinity Builder, Phosphate treatment, etc.

 

Know More

Condensol Amine Corrosion Inhibitor

SKU:RXSOL-50-5005-025

Concentrated liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great protection and neutralization of acidic gases, such as CO2.

Know More

Boiler Water Test Kit

SKU:RXSOL-62-5502-001

One kit for alkalinity, chloride, phosphate, and pH of boiler water testing.


 

Know More

How a Boiler Program Works

1) Pretreatment

Softening/RO + dosing of oxygen scavenger and alkalinity builder in feedwater to minimize O₂, hardness, and CO₂ entry.

2) Boiler Water

Maintain pH/alkalinity and residual phosphate/polymer to control scale; monitor TDS and blowdown.

3) Condensate

Use neutralizing/filming amines to protect return lines against carbonic acid and reduce iron pickup.

4) Monitoring

Routine tests: pH, PO₄, sulfite/DEHA, conductivity, hardness, iron, silica; adjust setpoints seasonally.

Maintenance Tips for Efficient, Safe Boilers

Keep Oxygen Out: Fix feedwater leaks, maintain deaerator temperature/venting, and hold sulfite/DEHA residuals within spec.
Control TDS with Smart Blowdown: Track conductivity and automate surface blowdown to hold target cycles and reduce fuel wastage.
Balance pH & Alkalinity: Stay within OEM-recommended ranges; too low invites corrosion, too high risks caustic embrittlement/foaming.
Watch Hardness & Silica: Any hardness carryover signals pretreatment issues—inspect softeners/RO and regeneration schedules.
Protect Condensate: Deploy neutralizing amines where CO₂ ingress occurs; consider filming amines for long return lines.
Descale & Clean Safely: Plan offline acid descaling/alkaline boil-outs with passivation; always neutralize and flush per procedure.
Log Everything: Daily readings (make-up, fuel, loads, test results) enable trend-based optimization and early fault detection.
Seasonal Recommissioning: For intermittent/standby units, use layup oxygen scavengers and maintain desiccant/nitrogen or wet storage chemistry.

FAQs

What is the benefit of Oxygen Scavenger Boiler Oxy Control?

It rapidly removes dissolved oxygen to prevent corrosion in low and medium-pressure boilers, while also neutralizing chlorine and biocides that may harm sensitive systems.

How does OxyShield Plus Oxygen Scavenger work differently?

OxyShield Plus offers extended condensate protection because it is volatile—it passes into steam and continues scavenging oxygen in condensate lines, while also promoting protective film formation.

When should I use One Shot Universal Liquitreat 100?

One Shot is a multipurpose treatment that controls rust, scale, and sludge. It’s ideal for small/medium boilers where a single product for scale inhibitors, oxygen scavenger, and alkalinity control is more convenient.

What does ADJUNCT Hardness Control do?

It reacts with calcium hardness in boiler feed water and converts it into a soft, non-adherent sludge that can be removed via blowdown—preventing scale formation.

Why is Alkalinity Builder pH Booster important?

It raises boiler water alkalinity, stabilizes pH, and prevents corrosion caused by acidic conditions in boilers and condensate lines.

How does the Corrosion Scale Inhibitor for Boilers protect my system?

It uses a polymer blend to control calcium, magnesium, silica, and phosphate deposits, preventing hard scale and corrosion inside the boiler tubes.

What is the purpose of the Defoamer for Boilers?

It immediately knocks down foam at low dosages, preventing priming and carryover. It is compatible with other boiler treatments like oxygen scavengers and phosphate programs.

When should I use Condensol Amine Corrosion Inhibitor?

This product protects condensate return lines by neutralizing acidic gases like CO₂ and preventing metal corrosion, ensuring clean and safe condensate.

Why is a Boiler Water Test Kit necessary?

Regular testing of alkalinity, chloride, phosphate, and pH ensures proper chemical dosing, prevents corrosion/scale, and verifies that the boiler program is under control.

Why is boiler water treatment necessary?

Boiler water naturally contains dissolved oxygen, hardness salts, and impurities. Without treatment, these cause corrosion, scaling, foaming, and unsafe boiler operation.

What is the difference between oxygen scavengers like Sulphite and DEHA?

Sulphite reacts quickly and is cost-effective but only works in the boiler water. DEHA is volatile, so it travels with steam to protect condensate lines as well.

How often should I check my boiler water quality?

Daily checks for pH, oxygen scavenger residual, and conductivity are recommended. Weekly tests should include hardness and alkalinity. A test kit helps automate these checks.

What causes foaming in boilers and how do I prevent it?

Foaming is usually due to oil/organic contamination or high dissolved solids. A defoamer helps immediately, but proper blowdown and treatment are the best long-term solutions.

How does hardness control help?

Hardness (calcium/magnesium) forms scale on boiler tubes, reducing heat transfer and efficiency. Hardness control chemicals convert it into removable sludge.

What is boiler carryover and why is it dangerous?

Carryover occurs when water (with dissolved solids) enters the steam line. It can cause turbine damage, contaminated steam, and false level readings. Defoamers and correct blowdown help prevent this.

What’s the role of condensate treatment?

Condensate can absorb CO₂, becoming acidic and corroding return lines. Neutralizing or filming amines are dosed to protect condensate systems.

How does scale prevention improve efficiency?

Even a thin layer of scale reduces heat transfer, increasing fuel consumption. Scale inhibitors keep salts dispersed, preventing hard deposits and saving energy.

Need a tailored boiler program?

Share boiler pressure, make-up water source, condensate return %, and current challenges. We’ll recommend a precise package.

Safety: Follow your site’s HAZOP and OEM limits. Products may have regulatory constraints by region; consult SDS/TDS before use.

Copyright © 2021 Powered By RXMARINE - All Rights Reserved