Skip to main content
Email :rxmarinechemical@gmail.com
Contact: 91 08069976670,
91 08069976671 , 91 08069976672

TERMAL FLUID DESALTER BATH HEATER

TERMAL FLUID DESALTER BATH HEATER
SKU
RXSOL-41-8690-025
Supply Location::
Locations

TERMAL FLUID DESALTER BATH HEATER manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of TERMAL FLUID DESALTER BATH HEATER at a competitive price from us. We have ready stock of TERMAL FLUID DESALTER BATH HEATER in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.


RXMARINE CHEMICAL TAG::
Category
Note

 Note:
1)Hot Oil bath is without nitrogen blanketing and open vent to Atmosphere:
2)Operating temperature range is 200-240 oC.
3)Compaitable Oxidaion Inhibitor shall be blended to enhance service life of the bath fluid oxidation inhibitor shall not be supplied.
4)Vendor to submit MSDS and product datasheet for the supplied Bath Fluids complete with chemical product and company identification, composition and / or information on Ingredients, Hazards Identification, First Aid Measures, Fire & Explosion data,accidental release measures, handling & storage. Exposure control & Personal protechtion, Physical and chemical properties,stability and reactivity Data, Toxicological and Ecological information,  Disposal Consideration transport, Regulatory and other information , if any.
5)Heat Transfer Parameter is used to evaluate the heat transfer coefficient, where
K= Thermal Conductivity of bath fluid, BTU/Hr-ft-F
C= Specification heat of bath fluid, BTU/Ib-F
p=Density of bath fluid, ib/ft3
B=Coefficient of thermal expansion of bath fluid. 1/0F
U=Viscosity of bath fluid,cp
All these parameters are calculated at 200oC
6) Heat Transfer coefficient for the stagnant bath fluid with natural convecttion at temperature >200oC to be specified with the calculation procedure used.

 

Property                                                ASTM Test Method UOM Product Specification
Kinematic Viscosity   

D445

CST

≤ 50°C@ 40°C
      ≤ 8@ 100°C
Pour Point       D5950

°C

≤ -10
Flash Point (Open Cup) D 92

°C

≥250
Fire Point D 92

°C

Can be removed

Auto-Ignition Temperature

D 2155

°C

≥350
Vapour Pressure D 2879 KPa ≤2.75@ 200°C
    KPa 0@ 50°C
Initial Boiling point D2887

°C

390 -440
Max.Bulk Temperature  

°C

≥250
Max. Film Temperature  

°C

≥340
Coefficient of Thermal Expansion D1250-80

1/°C

<0.0008 for complete operating range (up to 250°C )

Thermal Conductivity,(k)

  W/M-K 0.12 @200°C

Specific Heat, (C)

  KJ/KG-°C 2.12 @200°C

Density, (p)

  KG/M3 840@15°C

Oxidation Stability Test

D943   Vendor to advise (Note 1,2,3)

Thermal Stability Test

D-5800   Vendor to advise (Note 1,2,3)

Heat Transfer Parameter @ 200°C

Calculated   >1.35 x 10-4

Copyright © 2021 Powered By RXMARINE - All Rights Reserved