Corrosion Inhibitor Zinc Based
LIQUID COOLING WATER CORROSION & SCALE INHIBITOR RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System This is free from metal content like chromates, zinc or other metals.
Code: RXSOL-40-4029-025
Other Equivalent Brand
Corrosion Inhibitor for Open Cooling Circulating System, ROCOR OC, TRASAR 3DT 250, Corrosion Inhibitor with Zinc salts and Polyphosphates
Short Description: Corrosion Inhibitor with Zinc salts and Polyphosphates
Generic Name: Zinc Based Corrosion Inhibitor
Active Matter: 54-63
Application:
Corrosion Inhibitor OPEN Cooling System scientifically formulated to keep clean open recirculating systems and also prevent from scale formation . Chemically Corrosion Inhibitor OPEN Cooling System.
Corrosion Inhibitor OPEN Cooling System scientifically formulated to keep clean open recirculating systems and also prevent from scale formation . Chemically Corrosion Inhibitor OPEN Cooling System will disperse scale and corrosive products, silt etc and can be used as an anti-foulant along with other treatments.
Easy to fed Corrosion Inhibitor OPEN Cooling System directly from the drum or from a stock dilution tank. The slug feed method can also be used.
Using Procedure:
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System is highly concentrated cooling water treatment product, Its small dosage from 0.5 – 1 liter per 10 Tons of Cooling Water. The source of .
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System is highly concentrated cooling water treatment product, Its small dosage from 0.5 – 1 liter per 10 Tons of Cooling Water. The source of water also directly affecting its dosage as The dosage depends on the quality of the supply water ( Total hardness and Chloride content as low as possible) . Control is by simple colourismetric test.
Optimum result of COOLING SYSTEM can be obtained by maintaing pH level 8 to 8.5 and Total phosphate level should be maintained between 20 and 30 ppm.
Feel free to ask for RXSOL PHOSPHATE TEST KIT, RXSOL HARDNESS TEST KIT, RXSOL CHLORIDE TEST KIT. We are keeping full range of TEST KIT.
Note:
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System compatible with nylon, neoprene or rubber jointings. RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System is a.
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System compatible with nylon, neoprene or rubber jointings.
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System is a combined dispersant and anti-foulant and corrosion inhibitor which is specially formulated for the prevention of scale, deposits and corrosion in open fresh water, cooling systems.
Technical Specifications:
PHYSICAL CHARACTERICS
Appearance : Clear Liquid - Also available in PINK colour
Specific Gravity : 1.10 to 1.20
Flash Point : Non Flammable
Freezing Point : 0 Degrees Cent.
Remarks:
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System product does not require additional acid treatment.
ADVANTAGES of RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System
Clean Surfaces - Maximum heat transfer -
Its regular doses increases Higher efficiency
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System - Reduced Maintenance down time - Increased production
Non Toxic - Easy and Safe in use
RXSOL OC is Corrosion Inhibitor OPEN Cooling water circulation System Liquid manufacturer and supplier in Mumbai, Turbhe Pawana MIDC, Gandhidham, Visakhapatnam, Chennai Ennore, Kolkata, Haldia, Ajman, Fujairah, Dubai, Sharjah, Dubai, Muscat, Oman, Sohar, Barka, Canada, SUDAN, Yemen
Packing Size: 25.00 Kg.PWD
Available Packing Size: