Control of Hydarazine level in Boiler water is very important. As proper level maintenance protect metal machinery parts from corrosion, However, precautions must be taken to prevent excess dose of hydrazine chemical as excess hydrazine will begin to decompose at temperature above 200oC to form Ammonia.
Hydrazine is one of popular an alternative Oxygen Scavenger. It is very important to protect boiler components from feed boiler water corrosion.
For Hydrazine Test Kit mail us to get discounted price... Email : mail@rxmarine.com
Following the procedure above, the concentration in ppm of Hydrazine in the Boiler Water will be obtained. According to the Boiler’s working conditions, and the results obtained the dosage of Oxygen Scavenger / Hydrazine must be adjusted considering the dose chart. For effective boiler water treatment with Hydrazine and in order to avoid any problem of Oxygen corrosion, the test at the initial period of use of RXSOL Oxygen Scavenger must be performed every day. Once a small concentration of Hydrazine obtained in the Boiler water then the test could be repeated every 2–3 days.
Full set of Hydrazine Test Kit available at our all localtion of India and Middle East. Mail us to get discounted price of Hydrazine Test Kit. Email : mail@rxmarine.com
HYDRAZINE TEST KIT is used for the determination of Hydrazine content level in the Boiler’s Water. The test must be performed when in the vessel’s Boiler Water Treatment used hydrazine ingredient to control rust and corrosion RXSOL-50-5022-025 / RXSOL-50-5007-025 / RXSOL-19-1541-025. This is an activated hydrazine solution (Hydrazine with a catalyst for faster reaction with Dissolved Oxygen,) and applied for marine and industrial Boilers in low, medium and high pressures.
We are Hydrazine Test Kit supplier in Ennore, Chennai, Mumbai, JNPT, Manglore, GOa, Kandla, Gandhidham, Sikka, Mundra, Kolkata, Haldia, Pirpav, Dubai, Sharjah, Fujairah.
Hydrazine Hydrate Amine used as Oxygen scavenger on ultra high pressure industrial sites
No oxygen is entering the boiler with the feed water when hydrazine is present in the water.
The objective is to maintain a hydrazine residual between 0.05-0.2 ppm depending on operating pressure and boiler designe. Actual consumption is determined under operating conditions. A normal dosage is approximately 1 ltr. per day, depending of system layout.
Hydrazine is a convenient reductant because the by-products are typically nitrogen gas and water. Thus, it is used as an ANTIOXIDANT, an oxygen scavenger, and a corrosion inhibitor in water boilers and heating systems.
Hydrazine is mainly used as a foaming agent in preparing polymer foams.
No oxygen is entering the boiler with the feed water when hydrazine is present in the water.
Best Price supplier of Hydrazine Hydrate amine in Mumbai, Dubai, Muscat, Nairobi, Canada
Hold Brite Ship Hold Ceaning Detergent USING procedure
Cargo hold cleaning
For heavily soiled areas, a preliminary cleaning is required. If surface is heavily contaminated, higher concentrations of the product in water can be used. When used for spot cleaning, apply by hand spraying neat or prepare a 20% solution, and allow solution to penetrate soil for about 30 minutes before rinsing off with water. Always wash off before chemicals dry on the surface.
Heavy Soil deposition Use Undiluted from to 20-50% diluted with water.
Medium soil deposition 10-20% diluted with water.
Light Soil ( general degreasing ) 5-10% diluted with water.
Hold brite can be applied by brushing, scrubbing or spraying method. And it can be used neat or after dilution ratio from 10 to 25% with water. For heavily soiled and contaminated areas, higher concentrations of the product in water can be used, even neat concentrated holdbrite can be directly applied.
Spray cleaning solution of holdbrite on complete hold surface area and give 20 -30 minutes ( before surface dry ) time to complete alkalinity effect as well as cleaning effect with deposited cargo, then clean through high-pressure fresh water. 2nd wash can be repeated to get optimum result.
Two important feature of Holdbrite makes unique ship hold cleaning detergent.
A. Holdbrite resulting high foam to stick to the surface longer.
B. Alkaline nature effectively neutralizes acidic residue formed by the residue.
Available packing is in 20, 25, 50, 210 Ltr
Stock supply point : Sikka, Mundra, Kandla - Deen dayal, Surat - Hazira, Mumbai, Goa, Manglore, Chennai - Ennore, Visakhapatnam - Gangavaram, Kolkata - Haldia, Paradip, Fujairah - Dubai - Sharjah.
HOLD Brite RX resulting high foaming action during high pressure cleaning. High foam is beneficial to apply on vertical surface and can stand more stick to the surface longer, before drying. For heavily soiled areas, a preliminary cleaning is required. If surface is heavily contaminated, higher concentrations of the product in water can be used, even neat if contamination persists.
Hold bright When blasted through a foam gun high pressure machine RICH dense foam generated. Hold Bright RX formulated with extreme rich Foam Formula to apply on vertical surface. We are keeping ready stock at Visakhapatnam - Gangavaram, Chennai - Ennore, Kolkata - Haldia, Paradip, Mumbai, Kandla Deendayal port- Mundra, Fujairah - Dubai, Sharjah.
Lime Cleaner rapidly removes lime scale deposits. Its chemical formula start working with lime scale in a second and dissolve hard scale and lime. Commercially we are manufacturing Lime Cleaner in 25. 50 Ltrs packing. Due to acidic nature of LIME CLEANER, it effectively reacts with limestone, and its strong formulation attack and dissolve to eliminate caustic lime deposits and dry lime. We are one of largest Lime cleaner manufacturer and supplier in Mumbai - JNPT, Visakhapatnam - Gangavaram, Chennai - Ennore, Kolkata - Haldia - Paradip, Kandla - Mundra - Sikka - Hazira, Fujairah, Sharjah, Dubai, Abudhabi.
Email : mail@rxmarine.com for INDIAN coastal requirement
mail@dubichem.com for Middle East requirment
Oily deposits in steam boilers are a result of oil contamination of the feed water. Most often, the source of the oil is some part of the condensate and return system.
Fuel oil and cargo oils may contaminate the condensate via leaks in the oil heaters or tank heating coils. Lubricating oils may be picked up from steam driven machinery.
Oil deposits can be removed from boilers, L.P. steam generators, etc., by circulating a 2-5% solution of Heavy Duty Cleaner (Emulsifier) through the equipment. Heavy Duty Cleaner (Emulsifier) should never be used as an on-line cleaner. All cleaning should be done off-line.
For maximum cleaning efficiency, the cleaning mixture should be heated to 50° - 60°C (122° - 140° F) and maintained at this temperature during the cleaning operation. If adequate heat is not available, effective cleaning can be accomplished at temperatures as low as 25° C (77° F) using additional time. Carbonized oil or coke may require a two-step cleaning process using FOTTM fuel oil treatment followed by Heavy Duty Cleaner.
Heavy Duty Cleaner available in 25 Ltrs packing. And we are most popular Heavy Duty Cleaner manufacturer and supplier in Mumbai, Fujairah, Muscat, Kolkata, Visakhapatnam, Chennai, Ennore, Haldia, Gandhidham
Question : Why uses of alkaline cleaner prohibited to clean fatty acid contains substances like veg oil, Animal oil etc ?
Answer : Neutral HCF supplier and stockist at all Indian and UAE - Middle East Coastal. HCF Neutral chemical importance is to emulsify vegetable oils and animal oils and fats residue with less foaming effect. Chemically if you can understand oil and fat which contain FATTY ACID while the general cleaner is alkaline in nature which is resulting greasy mass oncoming contact with Fatty Acid and Alkali cleaning material. To avoid the formation of GREASE like substance inside the tank, it is very important to take care of an alkaline cleaner with such cargo. On the other hand HCF Neutral ( free from any kinds of alkali mixture ) emulsifying oils particle and makes water soluble to remove from zinc-silicate coated tanks surface.