SULFATE TEST KIT

SULFATE TEST KIT

SULFATE TEST KIT

Turbidimetric Photometric Method (0-50ppm) Principle / Concept   This method is based on the precipitation of sulfate ion in a hydrochloric acid medium with barium chloride in such a manner as to.

Turbidimetric Photometric Method (0-50ppm)

Principle / Concept  

This method is based on the precipitation of sulfate ion in a hydrochloric acid medium with barium chloride in such a manner as to form barium sulfate crystals of uniform size.  The glycerol sulfate solution is used to maintain proper crystal size, and control of the stirring and waiting times is necessary to obtain reproducible result.  The resultant turbidity is measured at a wavelength sensitive to turbidity on a photometer.  The blank serves to partially cancel out interferences due to color and suspended matter. 

Apparatus Required :::  

Filter photometer complete with assorted laboratory glassware.  ::: RXSOL-62-6198-001 doesn't include this apparatus

Chemicals Required

Glycerol Sulfate Solution   ::: Part No.  RXSOL-62-6198-002    http://rxmarine.com/Glycerol-Sulfate-Solution
Barium Chloride (Natural )  Solution  ::: Part No. RXSOL-60-6263-250  rxmarine.com/Barium-Chloride-Solution
Sulfate Standard  ::: Part No.  RXSOL-62-6198-003   http://rxmarine.com/Sulfate-Standard-Solution

Code: RXSOL-62-6198-001

Other Equivalent Brand Sulfate Test Kit Indicator.

Short Description: This method is based on the precipitation of sulfate ion in such a manner as to form compound sulfate crystals of uniform size.

Application:

This procedure uses a wavelength of 420 nm and a cell with a light path of approximately 10-mm. First prepare a calibration curve for the photometer using successive dilutions of the sulfate standard .

This procedure uses a wavelength of 420 nm and a cell with a light path of approximately 10-mm. First prepare a calibration curve for the photometer using successive dilutions of the sulfate standard to adequately cover the range of sulfate in the samples to be tested.  The dilutions of the standard should be treated in exactly the same manner as that shown below for analysis of the water samples.  Using a 50-ml plastic graduate, add 50 ml of sample to a 125-ml glass flask. Pipet 10 ml of glycerol sulfate solution into the flask and swirl the solution. Pipet 5 ml of distilled water into the flask, swirl the solution and use this solution to set the photometer at zero absorbance. Discard the solution and rinse the flask with distilled water. Into a second 50-ml sample, pipet 10 ml of glycerol sulfate solution and swirl. Adjust the temperature of the sample to 70 to 75F, and pipet 5 ml of neutral barium chloride solution into the same flask. Stir the solution by rotating a rubber paddle between the palms at moderate speed for exactly five seconds. Wait exactly five minutes, and then measure the absorbance on the photometer. 

Calculation of Results  The sulfate concentration in parts per million as SO4  is obtained by reference to the prepared sulfate calibration curve. 

Limitations of Test 

Color or large amounts of suspended matter will interfere with this method,  but some suspended matter may be removed by filtration. Also the presence of color and suspended matter is compensated for to some extent by the blank determination. Silica in excess of 500 ppm will interfere, and in samples containing large amounts of organic material, it may not be possible to precipitate barium sulfate satisfactorily.  

Note:

Water Testing Procedures Manual ( Full Range Lab testing   Methods with standard  composition ratio Of Reagents  ::: Available with us  at 2700 INR or 54 US$ or 207 AED   SULFATE TEST The principal pr.

Water Testing Procedures Manual ( Full Range Lab testing   Methods with standard  composition ratio Of Reagents  ::: Available with us  at 2700 INR or 54 US$ or 207 AED

 

SULFATE TEST

The principal problem potential posed by sulfate ions in water is the possibility of calcium sulfate scale formation.  Precipitation of calcium sulfate can occur when high concentrations of both calcium and sulfate exist simultaneously.  There are three primary areas of water treatment in which calcium sulfate precipitation may occur boilers, cooling systems, and ion exchangers operating in the hydrogen or acid mode.

 

 

In boilers, calcium sulfate scale formation has been reduced to a minimum by modern treatment practices.  The low hardness levels largely preclude calcium sulfate boiler scale.    By contrast, cooling systems are subject to calcium sulfate scale deposition because the makeup is usually not treated for hardness removal.  Cooling water is usually treated with sulfuric acid for pH control, and the makeup is cycled, i.e. concentrated.  Calcium sulfate scale deposition can  result unless the cycles of concentration are properly controlled in conjunction with the proper use of scale control chemicals.  Cation ion exchangers regenerated with sulfuric acid also can pose a major calcium sulfate problem. Calcium sulfate precipitation can be avoided by controlling the acid concentration and the flow rate through the exchanger

Remarks:

 

SULFATE TEST KIT manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of SULFATE TEST KIT at a competitive price from us. We have ready stock of SULFATE TEST KIT in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Packing Size: 1.00 Bottle

Available Packing Size: 30 ml, 50 ml, 100 ml, 200 ml, 500 ml, 1 Ltr.

HASHTAG:

#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant

#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable

#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater

#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

TAGS

Copyright © 2021 Powered By RXMARINE - All Rights Reserved