Descaling Chemical Compound for Chiller, Condenser tube of Central AC Plant
Descaling Chemical viscous Compound Suitable for Descaling of Copper tube of Chillers and Condenser of Air Conditioning Plant. Advanced formulation and Non Corrosive to material Non Polluting and Effective to remove Scale deposited inside Copper tubes. This Compound is Safe to handle also.
Code: RXSOL-41-8865-025
Other Equivalent Brand Descaling Chemical Compound for Chiller Condenser tube of Central AC Plant
Short Description:
Descaling Chemical Compound Suitable for Descaling of Copper tube of Chillers and Condenser of Air Conditioning Plant
Generic Name: Hard and thick scale dissolving chemicals
Active Matter: 63-72
Descaling Chemical Compound for Chiller, Condenser tube of Central AC Plant
Application:
RXSOL-41-8865-025 contains a powerful dissolving agent for various mineral compounds. Early stage uses of RXSOL-41-8865-025 prohibit scales build up which results in tube blockage, or regular cleanin.
RXSOL-41-8865-025 contains a powerful dissolving agent for various mineral compounds. Early stage uses of RXSOL-41-8865-025 prohibit scales build up which results in tube blockage, or regular cleaning is recommended as well. It is impossible to do a circulating cleaning when the tube is completely blocked.
* Calcium sulfate is easier to be formed when the temperature goes higher.
Using Procedure:
The most effective method of RXSOL-41-8865-025 is circulation for large systems or components. In the case of small components, the soak method in an immersion bath can be used. If the equipment to be clea.
The most effective method of RXSOL-41-8865-025 is circulation for large systems or components. In the case of small components, the soak method in an immersion bath can be used.
If the equipment to be cleaned is contaminated by oil, grease, sludge or carbonised oil, then pre-cleaning with RXSOL-20-2002-SC or Rxsol-10-1006 is necessary.
Note:
Descaling Chemical Compound for Chiller, Condenser tube of Central AC Plant manufacturer and supplier in INDIA and Middle East. We have stock point in Navi Mumbai - Turbha, Mumbai, JNPT, Surat, Gandhidham,
Descaling Chemical Compound for Chiller, Condenser tube of Central AC Plant manufacturer and supplier in INDIA and Middle East. We have stock point in Navi Mumbai - Turbha, Mumbai, JNPT, Surat, Gandhidham, Mundra, Kandla, Chennai, Ennore, Vizag, Visakhapatnam, Kakinada, Kolkata, Haldia, PAradip, Manglore, Goa. And in GULF we have supply range for Fujairah, Dubai, Sharjah, Abu Dhabi, Saudi, Kuwait.
Our name is very popular for producer and exporter of Descaling Chemical Compound for Chiller, Condenser tube of Central AC Plant
Technical Specifications:
Descaling Chemical compound Should have following Properties
Odour |
Characteristic smell |
Appearance |
Viscous Liquid, soluble in water |
pH (Neat) |
< 2.0 at 100 % concentration |
Boiling point |
~ 100 °C at 760 mm /Hg |
Vapour pressure |
105.5 at 20 deg C |
Specific gravity (water=1) |
1.20±0.05 |
Freezing point~ |
30 °C at 760 mm/Hg |
Solubility with water at 20 degree C |
100% |
Flammable | Non combustible |
Remarks:
RXSOL- 41-8865-025 should alway be used in plastic bucket. RXSOL-41-8865-025 should always be added in , never add water in RXSOL-41-8865-025.
RXSOL-41-8865-025 shows fast dissolving property with raising of temperature up to 70 c. And on hard and thick deposition the solution is circulated for 12 to 36 hours. ( Depending upon the hardness of the scales ). Brushing with an iron brush gives better results in getting rid of hard scales. ( Refer below TIPS for CLEANING )
In Melting Industry
RXSOL-41-8865-025 is often the automatic choice to do away with the scales from coils, cables, cooling jackets, heat exchangers or linings in steel plants.
Features, Benefits and Applications
- Unlimited shelf life.
- Easy to rinse off.
- Fast and effective scale remover.
- Removes scale and rust from condensers, evaporators, heat exchangers,Rediator etc.
- Removes water scale from boilers.
RXSOL-41-8865-025 dilute with fresh water as 5-30%, solution depending on scale.Make a circulation system so as to allow the solution to enter through the lowest point and leave through the highest point of the equipment, which is to be descaled.
TIPS for CLEANING
Fill up the whole system with the solution and circulate through a centrifugal pump.
At the initial stages, pH of the solution is generally at 2 to 3 there is increase in the pH of the solution, during reaction.The increase in the pH of the solution during circulation reflects on going reaction. Add more quantity of RXSOL-41-8865-025 and continue circulation, in case of the pH level being 4.5 to 5. If circulation of system shows constant pH 2 to 3 after time confirms the completion of the process of descaling.
The process of descaling is checked by a periodical pH testing of the solution.
For silica scales and very hard scales, power and liquid forms of RXSOL-41-8865-025 is recommended.
For the prevention of further scaling in melting industry, RXSOL-41-8865-025 is recommended.
NOTE : After using RXSOL-16-1008-060 ( After completion of descaling ) rinse all equipment and metal surfaces at least one time with a 0.5% solution of RXSOL-20-2059-025 in fresh water. This solution should be circulated for 2-4 hours or until pH value comes 6-7. This will neutralize any remaining acid and passivate steel surfaces.
Descaling Chemical Compound for Chiller, Condenser tube of Central AC Plant available in Chennai - Ennore, Mumbai, Visakhapatnam- Gangavaram, Kolkata - Haldia, Kandla - Gandhidham, Fujairah - Dubai
#Chiller_Descalant
#ChillerDescalant_manufacturerSUPPLIER
#ChillerDescalant_MuscatDUBAI
Packing Size:25.00 Ltr.
Available Packing Size:
Descaler for Chiller plant available in Dubai, Muscat, Mumbai, Kolkata, Chennai, Vizag, Surat, Gnadhidham in 5, 20, 25, 60 Heavy duty HMHDPE carboy. Factory sale for our regular customer on heavy discounted scheme available.
Article News: