Browse : A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z  
Featured Products 

Acid corrosion Inhibitor RXSOL 213

Product Description | Product Application | Product Notes| Product DOSE
Inhibitor for ACID Acid corrosion Inhibitor RXSOL 213  is an organic, liquid, cationic corrosion inhibitor especially designed to inhibit the attack of hydrochloric acid oiron and steel during indust [+] Read More...
Code:
RXSOL-19-1503-005
Other Equivalent Brand

Rodine 213, Corrosion Inhibitor for Hydrochloric Acid Cleaning, Lith Solvent 803

Short Description:
The addition of Acid corrosion Inhibitor RXSOL 213, inhibitors to hydrochloric acid solution provides maximum protection for equipment during,The removal of lime deposits or water scale from power plant boilers and piping systems and from evaporating equi
Active Matter:
93-98
IMPA Code:
HS CODE38249022
Acid corrosion Inhibitor RXSOL 213
Application:
The addition of Acid corrosion Inhibitor RXSOL 213, inhibitors to hydrochloric acid solution provides maximum protection for equipment during: A. The removal of lime deposits or water scale from powe [+] Read More...
Using Procedure:
For each For each 1000ltrs of pickling bath RXSOL 213 must be added at the rate of 1 to 5ltrs (1.1 - 5.7kgs)* hydrochloric acid solution, not less than the following amount of Acid corrosion Inhibitor RXSOL [+] Read More...
Note:
Storage and Disposal Acid corrosion Inhibitor RXSOL 213 and will not freeze at temperature as low as -20° Fahrenheit. Below 0° Fahrenheit,Acid corrosion Inhibitor RXSOL 213 become very viscous and may be [+] Read More...
Technical Specifications:

ACID inhibitor for HCl, Hydrochloric Acid. 

During Acidization corrosion prevention must required to protect metal surface from ACID effect. Inhibited hydrochloric acid  (HCl), HF doesn't damage metal surface. 
Remarks:

Acids and corrosive materials are used to enhance production and to stimulate reservoirs therefore special care is required to ensure that casing, tubing strings and downhole equipment are not damaged. Blend of ACID with Acid corrosion Inhibitor RXSOL 213 protect your downhole equipment and metal tubulars.

Exhibits excellent sequestration of metal ions and threshold inhibition of metal salt precipitation. Its hydrolytic stability makes it a versatile ingredient for applications requiring efficient metal ion control. Acid corrosion Inhibitor RXSOL 213 excellent scale and corrosion inhibition and good thermal tolerance ability.

Acid corrosion Inhibitor RXSOL 213 have chemical properties of sequestration, deflocculation, threshold inhibition and hydrolytic stability etc. Acid corrosion Inhibitor RXSOL 213 also act as an organophosphoric acid corrosion inhibitor. It can chelate with Fe, Cu, and Zn ions to form stable chelating compounds. It can dissolve the oxidized materials on these metals’ surfaces.

Acid corrosion Inhibitor RXSOL 213 also resulting good corrosion and antiscaling effect. 

It's good resistance towards High and Low pH value makes it unique and better than that of other organophosphoric acids (salt). Acid corrosion Inhibitor RXSOL 213 also resulting high chlorine oxidation tolerance properties.

Acid corrosion Inhibitor RXSOL 213 has good antiscale and visible threshold effects. 

Acidizing inhibitors
Corrosion Inhibitor for Acid Pickling and Descaling of Boilers with Acids.
Acid Inhibitors used in hydrochloric acid pickling baths, for reducing metal loss during uses of acid.

When Acid like hydrochloric acid is used in system, it is needless to say that equipment can be protected without uses of Acid corrosion inhibitor.
 
Acid corrosion Inhibitor RXSOL 213 containing chelatig agent, acidic blend of complex alkyl pyridines, 1, 3, diethyl thiourea and many more to protects steel, brass and copper against the attack of acid. 
 
Can be use as single product for multiple acids, Easily soluble with all acid concentrations

Acid Corrosion inhibitor manufacturer. exporter and supplier in India Kuwait, UAE, Oman, Mumbai Maharastra, Chennai Tamilnadu, Kolkata WestBengal, Visakhapatnam Andhrapradesh, Gandhidham Surat Gujrat, Fujairah Dubai Sharjah Ajman Abudhabi, Oman Muscat Sohar, Canada, Nairobi Kenya Africa
Acid corrosion Inhibitor RXSOL 213
:
Packing Size:
5.00 Ltr.
Available Packing Size:
500ml, 1, 5, 10, 20, 25 Ltr packing available Acid Inhibitors used for acids like hydrochloric, sulphuric, sulfamic, citric, nitric, fluoric and phosphoric acid.
HASHTAG:
#MarineChemical #TankCleaner #OilFieldChemical #ChemicalManufacturer #ChemicalSupplier #WaterTreatmentChemical #ROchemicals #ReverseOsmosisChemical #Dispersant
#Demulsifier #WaterlessHandCleaner #AirCoolerCleaner #CarbonRemover #ScaleRemover #ActivatedAlumina #ActivatedCarbon #SilicaGel #Degreaser_Biodegradable
#DieselExhaustFluid #BlueLiquid #ToiletBlueWater_Juice #RigWash #OxygenScavenger #CoolingWaterTreatment #RoccorNB #CorrosionInhibitor #CalciumChloride #DIwater
#AlumPowder #MagnesiumSulphate #SodaAsh #SulfamicAcid #PotassiumChloride

RX MARINE INTERNATIONAL is most popular chemicals source in INDIA, Keeping ready stock at 5 LOCATION which includes Mumbai, Kandla - Gandhidham, Vizag - Visakhapatnam, Ennore - Chennai, Kolkata more then 3000 types of chemicals. Please click here to get PRODUCT Categories details http://rxmarine.com/Products

 

Mail Us for any PRODUCT related information and purchase inquiry : mail@rxmarine.com ( This mail is for customer / Buyer only ) And if you wants to add your hand as a supplier, And if you have volume manufacturing capacity of chemicals, pl. drop your mail at rxmarine@gmail.com ( This mail is for supplier only )