ACC PLUS is popular in marine sector to clean Diesel Engine Air Cooler and turbocharger compressor. Its effective surfactant formulation with Solvent easily dissolve hard oily and carbonecious deposits. Proper uses of ACC PLUS increases cooling efficiency of AIR COOLER.
Our New advance formulation of ACC PLUS air cooler cleaner also helps to clean and degreas maintainence area. And this product is fully water soluble after dilution with ware ACC plus can be use as degreaser also. And diluted solution of ACC PLUS can be kept in open cut drum or water bath, to clean daily uses of nut bolt and machinery parts. Simply dip oil contaminated parts in to diluted solution of ACC PLUS and keep for small period of time, this method can keep all maintence part clean and rust free. Here we can see that ACC PLUS having multiple cleaning action, Its presence on ENGINE area can avoid any additional degreaser requirement.
ACC Plus available with us in various size and packing of 20, 25, 50, 210 Ltr
For ACC Plus price and other related document like MSDS of ACC PLUS, you can mail us your inquiry ::: mail@rxmarine.com
ACC9 is industrial equipment maintenance air cooler cleaner for cleaning of the diesel engine charge Air cooler. ACC9 is Light yellow to brown colored water-soluble solvent, which emulsifies with water. ACC9 is blend of the selected specified solvent mixture which is safe in contact with all metals.
ACC-9 Air Cooler Cleaner Principally works as follows, with triple action :
1st Action : Non Corrosive Solvent present in ACC9 helps to dissolve all deposits, oil, greasy materials. 2ndly : While emulsifier increases Detergency property to enhance cleaning action of ACC-9. 3rd Important feature of ACC-9 the presence of inhibitors in ACC9 protect soft metal, we can say INHIBITOR makes solution safe to contact with all metals.
Medical grade Soda Lime as per IP/BP/USP standards.
Soda Lime is a well balanced mixture of Calcium and Sodium Hydroxides, which have high Carbon Dioxide absorption capacity.
Use in Hospitals:
Soda Lime is used to absorb expired CO2 during Anesthesia (in Operation Theatres).
Soda Lime is a Carbon Dioxide absorbent of choice for major hospitals in India & across the world.
Soda Lime are in breathable gas applications where Carbon Dioxide levels need to be controlled, for example in medical anesthetic breathing circuits. In these applications, the breathable air is recirculated for re-use and therefore any exhaled carbon dioxide needs to be removed in order to prevent a build-up of carbon dioxide to toxic levels.
Soda Lime has application in Anesthetic systems in the medical operations to remove expelled Carbon dioxide due to respiration carried out by the patient or the user.
Soda Lime with Color Indicator:
Soda Lime becomes less effective during use, the granules change their color.
Color Indicator is available in 2 types:
Pink to White Indicator on absorption of CO2
White to violet Indicator on absorption of CO2
Medical Application:
Soda Lime is used in medical applications for removal of carbon dioxide from breathable gas in anesthesia circuits and in hyperbaric oxygen treatment chambers. Akron Healthcare manufactures Soda lime for many of the world's leading medical equipment manufacturers and leading hospitals as per their customized specifications to suit their needs.
Shape:
The granule shape of Soda Lime ensures maximum CO2 penetration into the particles, by minimizing the distance to the centre of the particle, thereby increasing the CO2 capacity of the product. It absorbs carbon dioxide in oxygen based therapy based metabolism, in closed circuit anesthesia, in estimation respirators, breathing apparatus etc. Exhaled gases are circled back to the canister where CO2 absorption takes place and water and heat are produced. The warmed and humidified gas joins the fresh gas flow to be delivered to the patient. In Soda Lime absorption, the Carbon Dioxide first reacts with water to form carbonic acid, which then reacts with sodium hydroxide to form a soluble carbonate. The soluble sodium carbonate then reacts with calcium hydroxide to form an insoluble carbonate and replenishes sodium hydroxide. Exhaustion of its activity is indicated by the dye and accordingly the color changes from pink to white or white to violet depending on the indicator used due to absorption of Carbon Dioxide (CO2).
Soda Lime granules are available in various shapes that include irregular pebble shaped granules, uniform shaped granules, cylindrical shaped granules, d-shaped granules and pellet shaped granules depending on the intended application and customer specification.
The water content can also be varied depending on the application.
The point to be ensured is that the shape of the granules should maximize CO2 absorption and minimize dust formation.
Size:
Mesh size to use for Medical Purposes:
The appropriate mesh size is 4-8 mesh.
Medical Grade Soda Lime is presently available in different Granule Sizes or Size Range that include:
1.4-2.0 mm
2.0-2.8 mm
2.0 – 4.0 mm
2.0-8.0 mm
2.5-5.0 mm
2.8-4.75 mm
2.8-5.5 mm
4.0-8.0 mm
Why Carbohydrazide is better substitute of Hydrazine?
Carbohydrazide is used as an oxygen scavenger in water treatment for boilers. It is an alternative to the hazardous and potentially carcinogenic hydrazine. Carbohydrazide reacts with oxygen to make water, nitrogen and urea.
As proper level Carbohydrazide protect metal machinery parts from corrosion.
Carbohydrazide is one of popular an alternative Oxygen Scavenger. It is very important to protect boiler components from feed boiler water corrosion.
Carbohydrazide also Widely used in medicine, herbicides, plant growth regulators, dyes and other industries.
Carbohydrazide is widely used in the production of drugs, herbicides, plant growth regulators, and dyestuffs. Carbohydrazide is a white crystalline solid with a melting point of 153-154 °C. It decomposes upon melting. It is very water soluble and largely insoluble in organic solvents.
Carbohydrazide Uses and Application:
Oxygen scrubber: carbohydrazide is used as an oxygen scrubber in boiler systems. Oxygen scrubbers remove oxygen gas from the boiler system to prevent corrosion.
Polymers: carbohydrazide can react with many aromatic compounds to create polymers.Carbohydrazide can be used as a curing agent for epoxide-type resins.
Photography: carbohyrazide is used in the silver halide diffusion process as one of the toners. Carbohydrazide is used to stabilize color developers that produce images of the azo-methine and azine classes.
Carbohydrazide has been used to develop propellants stabilize soaps, and used a reagent in organic synthesis.
Why Traffic Film Remover TFR Cleaner ?
Traffic Film Remover TFR Cleaner is easy and effective to use. And safe TFR or the best way to wash your vehicle. Traffic film remover (TFR) products that will result and give your car a brand-new look without damaging its paintwork.
Email us to Get discounted Price for Traffic Film Remover...
How to Disinfect Water Using Calcium Hypochlorite
A.) Dissolve 1 teaspoon 60-78% granular calcium hypochlorite in 7 - 8 liters of water .
B.) Then add this solution 1 part to disinfect water to 100 parts water to be treated. Finally keep mixed water to settle completely for 20 - 30 minutes before drinking.
NOTE ::: Freshly prepared ( A.) solution is recommended to make 2nd step ( B.) drinking water.
Calcium Hypochlorite Granules and Calcium Hypochlorite Chlorine Tablet Manufacturer and supplier in India, Middle East, Oman, Kenya Africa
Chlorine Granules and Chlorine Tablet supplier in Dubai, Muscat, Nairobi, Canada.
Also feel free to ask for your chlorine Tablet and Chlorine Granules price, speciafication and supply for Fujairah, Dubai, Sharjah, Ajman, Abudhabi, Barka, Sohar Suhar, Kenya.
Email : mail@rxmarine.com ( For India )
: mail@dubichem.com ( For Middle East )
: mail@muscatchemical.com ( For Oman )
: mail@kenyachemical.com ( For Africa )
: chemicals@canadachemical.com ( for Canada )
MAGNESIUM SULPHATE (HEPTA HYDRATE 99.5% MIN are frequently used as RO CHEMICALS. To make water wholesome, testier and healthy many Mineral water manufacturers are adding these minerals frequently :
1st Option :Compbination of magnesium sulfate, potassium chloride
2nd Option :calcium chloride, magnesium chloride, and potassium bicarbonate.
sodium bicarbonate
3rd option : Magnesium sulphate and Potassium bicarbonate
Dose Level : 100ml of water, Mg=0.2mg; K=0.1mg
Per 100ml, Na=0.3mg; Mg=0.1mg
Follow these steps to prevent or to kill the moss from your lawn, garden, orchard or any other place.
- Mix 1/4 to 1/2 Pounds of RX Marine International Ferrous Sulfate with 4 gallons of water for every 1,000 square feet of lawn.
- Spray the solution you made on your entire lawn and concentrate on area with existing moss. (Note: you need to spray your entire lawn even the areas without moss to prevent future growth).
- Do NOT water the lawn after apply the Ferrous Sulfate treatment and allow several days to kill the moss.
- Get rid of the dead moss patches on your lawn. (Note: you could simply pick them out by hand.)
- Spread 5-10 Pounds of RXSOL Calcium Carbonate (Limestone) per 1,000 square feet of lawn to neutralize the acidifying effects of Ferrous Sulfate.
For further information like MSDS, Price, kindly mail us at: mail@rxmarine.com
Or give us a call at: +91 9322594669
USES:
Deep cleaning of outdoor condenser coils to restore efficiency and increase performance of the system.
DILUTION RATIOS:
Because RXSOL-16-1697-005 is highly concentrated, it must be diluted prior to use. Dilution also improves penetration into the coil and increases product performance. Actual dilution ratios will vary according to the application. The following is intended as a general
guideline:
- Up to 8-10 parts water to 1 par tRXSOL COIL CLEANER for light cleaning and brightening, when expanding foam is not required.
- 3-5 parts water to 1 part RXSOL COIL CLEANER for foaming action on difficult cleaning tasks.
- 1-2 parts water to 1 part RXSOL COIL CLEANER for use as a high foaming,aluminum finned, air cooled condenser coil cleaner.Use the minimum concentration required to accomplish your task.
Note: Do not use RXSOL-16-1697-005 at concentrations greater than 1:1 (less than 1 part water to 1 part RXSOL-16-1697-005 ). Rinse the treated surfaces as well as the surrounding area thoroughly after use.
APPLICATION METHODS:
Low pressure, acid resistant tank sprayers are recommended.
Regardless of application method, avoid inhalation of mist or contact of liquid or mist with skin.
SUGGESTED INSTRUCTIONS FOR USE:
- When handling RXSOL-16-1697-005 or any other strong chemical, be sure to wear chemical imperviousgloves,apron and splash goggles.
- Determine required dilution ratio for the specific application. It is recommended to start with a dilution ratio of 10:1 and increase concentration until the desired results are achieved.
- As with mixing all acids, place the desired amount of water into the tank and then add RXSOL-16-1697-005.
- Turn off fans and allow hot coils to cool before applying.
- Using plain water, wet both the condenser coil as well as the area surrounding the equipment. Wetting the coil with water aids in product penetration and performance.
- Apply the properly diluted product to the coil surface. Whenever possible, apply solution from the outlet side of the coil. Allow product to remain on surface, normally 5-10 minutes. Do not allow product to dry on the coil. Note: In extreme cases, application may have to be repeated to achieve desired results.
- If foaming does not occur, check for extreme grease buildup which will slow cleaning process. Foaming may not occur if coil is coated or painted.
- Rinse coils, tools and surrounding area thoroughly after completing the coil cleaning process
Condensor Coil Cleaner manufacturer and supplier in India UAE Oman Kenya Uganda Canada ::: rxmarinegroup@gmail.com