Why Traffic Film Remover TFR Cleaner ?
Traffic Film Remover TFR Cleaner is easy and effective to use. And safe TFR or the best way to wash your vehicle. Traffic film remover (TFR) products that will result and give your car a brand-new look without damaging its paintwork.
Email us to Get discounted Price for Traffic Film Remover...
How to Disinfect Water Using Calcium Hypochlorite
A.) Dissolve 1 teaspoon 60-78% granular calcium hypochlorite in 7 - 8 liters of water .
B.) Then add this solution 1 part to disinfect water to 100 parts water to be treated. Finally keep mixed water to settle completely for 20 - 30 minutes before drinking.
NOTE ::: Freshly prepared ( A.) solution is recommended to make 2nd step ( B.) drinking water.
Calcium Hypochlorite Granules and Calcium Hypochlorite Chlorine Tablet Manufacturer and supplier in India, Middle East, Oman, Kenya Africa
Chlorine Granules and Chlorine Tablet supplier in Dubai, Muscat, Nairobi, Canada.
Also feel free to ask for your chlorine Tablet and Chlorine Granules price, speciafication and supply for Fujairah, Dubai, Sharjah, Ajman, Abudhabi, Barka, Sohar Suhar, Kenya.
Email : mail@rxmarine.com ( For India )
: mail@dubichem.com ( For Middle East )
: mail@muscatchemical.com ( For Oman )
: mail@kenyachemical.com ( For Africa )
: chemicals@canadachemical.com ( for Canada )
MAGNESIUM SULPHATE (HEPTA HYDRATE 99.5% MIN are frequently used as RO CHEMICALS. To make water wholesome, testier and healthy many Mineral water manufacturers are adding these minerals frequently :
1st Option :Compbination of magnesium sulfate, potassium chloride
2nd Option :calcium chloride, magnesium chloride, and potassium bicarbonate.
sodium bicarbonate
3rd option : Magnesium sulphate and Potassium bicarbonate
Dose Level : 100ml of water, Mg=0.2mg; K=0.1mg
Per 100ml, Na=0.3mg; Mg=0.1mg
Follow these steps to prevent or to kill the moss from your lawn, garden, orchard or any other place.
- Mix 1/4 to 1/2 Pounds of RX Marine International Ferrous Sulfate with 4 gallons of water for every 1,000 square feet of lawn.
- Spray the solution you made on your entire lawn and concentrate on area with existing moss. (Note: you need to spray your entire lawn even the areas without moss to prevent future growth).
- Do NOT water the lawn after apply the Ferrous Sulfate treatment and allow several days to kill the moss.
- Get rid of the dead moss patches on your lawn. (Note: you could simply pick them out by hand.)
- Spread 5-10 Pounds of RXSOL Calcium Carbonate (Limestone) per 1,000 square feet of lawn to neutralize the acidifying effects of Ferrous Sulfate.
For further information like MSDS, Price, kindly mail us at: mail@rxmarine.com
Or give us a call at: +91 9322594669
USES:
Deep cleaning of outdoor condenser coils to restore efficiency and increase performance of the system.
DILUTION RATIOS:
Because RXSOL-16-1697-005 is highly concentrated, it must be diluted prior to use. Dilution also improves penetration into the coil and increases product performance. Actual dilution ratios will vary according to the application. The following is intended as a general
guideline:
- Up to 8-10 parts water to 1 par tRXSOL COIL CLEANER for light cleaning and brightening, when expanding foam is not required.
- 3-5 parts water to 1 part RXSOL COIL CLEANER for foaming action on difficult cleaning tasks.
- 1-2 parts water to 1 part RXSOL COIL CLEANER for use as a high foaming,aluminum finned, air cooled condenser coil cleaner.Use the minimum concentration required to accomplish your task.
Note: Do not use RXSOL-16-1697-005 at concentrations greater than 1:1 (less than 1 part water to 1 part RXSOL-16-1697-005 ). Rinse the treated surfaces as well as the surrounding area thoroughly after use.
APPLICATION METHODS:
Low pressure, acid resistant tank sprayers are recommended.
Regardless of application method, avoid inhalation of mist or contact of liquid or mist with skin.
SUGGESTED INSTRUCTIONS FOR USE:
- When handling RXSOL-16-1697-005 or any other strong chemical, be sure to wear chemical imperviousgloves,apron and splash goggles.
- Determine required dilution ratio for the specific application. It is recommended to start with a dilution ratio of 10:1 and increase concentration until the desired results are achieved.
- As with mixing all acids, place the desired amount of water into the tank and then add RXSOL-16-1697-005.
- Turn off fans and allow hot coils to cool before applying.
- Using plain water, wet both the condenser coil as well as the area surrounding the equipment. Wetting the coil with water aids in product penetration and performance.
- Apply the properly diluted product to the coil surface. Whenever possible, apply solution from the outlet side of the coil. Allow product to remain on surface, normally 5-10 minutes. Do not allow product to dry on the coil. Note: In extreme cases, application may have to be repeated to achieve desired results.
- If foaming does not occur, check for extreme grease buildup which will slow cleaning process. Foaming may not occur if coil is coated or painted.
- Rinse coils, tools and surrounding area thoroughly after completing the coil cleaning process
Condensor Coil Cleaner manufacturer and supplier in India UAE Oman Kenya Uganda Canada ::: rxmarinegroup@gmail.com
CHLORIDE TEST for DRILLING FLUID
Drilling and Completion Fluids
Chlorides
First of all test pH value of Mud, If it shows alkaline then neutralized by using phenolphthalein indicator with Sulfuric Acid. Then titrated with standard silver nitrate solution, using potassium chromate as indicator. The results are reported as parts per million chloride ion, although actually measured in terms of mg Cl ion per 1000 cm3 of filtrate. To determine the chloride content of an oil mud, the sample is diluted with isopropyl alcohol and then mixed with distilled water, neutralized to the phenolphthalein end point, and then titrated in the usual way.
The end point is difficult to detect using the silver nitrate method, and the results depend to some extent on the operator. Titrating with mercuric nitrate, using bromophenol blue as an indicator, is an alternative. The method gives a much sharper end point, which is particularly advantageous when titrating whole mud, especially oil muds.
We are well known name for Mercuric Nitrate supplier, Bromophenol blue supplier, Phenolphthalein supplier, Iso Propyl Alcohol supplier, Silver Nitrate supplier, Potassium Chromate, Distilled water supplier in Mumbai, Gandhidham, Chennai, Visakhapatnam, Kolkata, Fujairah, Sharjah, Ajman, Abudhabi, Dubai, Muscat - Oman.
Antifouling Hull Cleaning agent. specially formulated to Clean boat hull by quickly removing algae, lime, scale and chalking remove those hard to shift stains from fibreglass boats, Hull shaft area. Hull Cleaner uses a unique acid-surfactant blend designed to remove marine growth, hard water stains, rust, and calcium buildup.
Other Valuable Product for Engine room, cleaning and maintenance. Deck and hull. Tank and cargo hold cleaning:
AQUATUFF
METAL BRITE
BOLL CLEAN 2000 CLEANING AGENT
DISCLEANER
ENVIROCLEAN
RUST CONVERTER
AIR COOLER CLEANER
COLD WASH HD
CARBON REMOVER
DESCALING LIQUID
ULTRASONIC CLEANER
SODIUM HYPOCHLORITE (10-15 PCT)
Investigations have shown sodium hypochlorite to be an effective disinfectant having broad applications. Although a number of other disinfectants have been investigated, sodium hypochlorite appears to offer the best mix of low cost, ease of use, safety, and effectiveness in areas where there is enough water and water is not excessively turbid.
Mainly Condensate storage tank is specialized tank to get and store oil after condensation of fossil fuels during production. While the exact properties of any particular condensate tank may vary product wise, but generally used to store a mixture of hydrocarbon gases. After periodic interval of time its cleaning can help to reduce down time. We have one of our successful and powerful product called ORG-3, which is effectively dissolves and emulsify fossil fuels and mixture of hydrocarbon trapped in condensate tank.
We are keeping ready stock of ORG-3 at Fujairah, Mumbai, Chennai, Kolkata, Kandla. Our standard packing of Condensate storage tank cleaner - ORG-3 is 25 Ltr and 210 Ltr. For Middle East requirement pl. drop email at chemicals@dubichem.com while for India's supply use mail@rxmarine.com
From: Reny
Date: Wed, Jan 31, 2018 at 10:51 AM
To: rxmarine.com, dubichem.com
Need a reply
1.Is Biosol cleaner RXSOL-20-2019-025) compatible with Titanium plate and Nitrile gasket?
2.Is Descalex Polymer (RXSOL-40-1048-025) compatible with Titanium plate and Nitrile gasket?
3 If the plate heat exchanger volume is 2797 litres on the sea water side.That's the side where there has been contamination with heavy oil , how many litres of bio sol cleaner and Descaler Polymer do we need to order?
Need your feedback to the above queries
Thanks Regards
Reny
Dubai
General Manager
Gulf Sondex FZCO
Danfoss Heating Segment
Jebel Ali, Dubai – U.A.E
Reply:
Dear Sir,
1.Biosol cleaner RXSOL-20-2019-025 contians oil soluble formula it doesn't effect Titanium plate and Nitrile gasket.
2.Descalex Polymer (RXSOL-40-1048-025) is derivative form or ACIDIC polymer, it doesn't react with Titanium metal and Nitrile gasket
3.Recirculation is best option to clean heat exchanger, And if volume is 2797 litres on the sea water side means same or aditional 30% volume tank required to circulate the liquid. And required percentage of Biosol is 5 - 10 % of total liquid volume which means 100 to 150 Ltr BIOSOL is more then suffiecient to circulate in this case to clean as contaminatied with heavy oil. And after circulation of BIOSOL, remove all contaminated water from heat exchanger and tank. Then take other sea water / fresh water to dose Descaler Polymer, Its dose ratio is completely depends on deposition of scale inside the plate of heat exchanger. The solid mass of mineral deposits approximate mass calculation will help to use proper volume of RXSOL-40-1048-025 Descaler. As per gallon in concentrated form of RXSOL-40-1048-025 has the ability to dissolve approximately 1.5kg of scale mass So 3 to 20 percent of total volume depending on deposition of scaling materials required. 150 Ltr to 600 Ltr descalex polymer can be use to clean scale deposits. After use of RXSOL-40-1048-025 a 0.5% solution of Alkalinity Control infresh water should be used for neutralization.
Regards
Technical Support Team