Skip to main content
Email :rxmarinechemical@gmail.com
Contact: 91 08069976670,
91 08069976671 , 91 08069976672

USES OF ETHANOL

USES OF ETHANOL

 Here are some of the most common yet most effective uses of Ethanol. 

Degreaser Grime OFF as Kitchen Cleaning Agent

Degreaser Grime OFF as Kitchen Cleaning Agent

Degreaser GRIME OFF chemically reacts and emulsify stubborn grease and grime and due to its Economical dilution uses Grime Off is budget-friendly multipurpose kitchen cleanser.

Sodium Sulfite as Oxygen Scavenger

Sodium Sulfite as Oxygen Scavenger

The dosage of sodium sulfite or other oxygen scavengers may be calculated by looking at their reaction rate to remove the oxygen and then their residual dosage to provide a feedwater or boiler water residual.

Sodium Sulfite Example

The reaction rate is:
2Na2SO3 (7.88 ppm) + O2 ( 1 ppm) → 2Na2SO4

For the residual, 1.6 ppm Na2SO3 will yield 1 ppm SO3.

The total calculation equation to remove residual oxygen and provide a boiler water residual is:

Sodium Hexametaphosphate to precipitate calcium in low-pressure boilers

Sodium Hexametaphosphate to precipitate calcium in low-pressure boilers

Sodium Hexametaphosphate supplier

Sodium hexametaphosphate is a commonly used source of orthophosphate anion used to precipitate calcium in low-pressure boilers. With dispersants the calcium phosphate becomes a fluidized sludge capable of being blown down and out of the boiler before the calcium can form a deposit.

Example

The reaction rate is the first part of the equation and the residual the second part:

Chelant Treatment for Boiler

Chelant Treatment for Boiler

Chelant Treatment

EDTA dosage requirements and variations will be similar to phosphate in that there is a reaction and residual portion to the dosage calculation:

(Feedwater hardness) x (3.8) % active / 100 + ppm EDTA desired residual / (feedwater cycles) x % active / 100 = ppm EDTA Product 

Economical control would again be very difficult with fluctuations in feedwater hardness.

Oxygen scavengers for Boiler Water

Oxygen scavengers for Boiler Water

Oxygen scavengers are best fed to the storage section of the deaerator or feedwater tank. In most low-pressure industrial boiler systems, if oxygen remains in the feedwater and enters the boiler, it is too late to remove all of the oxygen and protect the boiler and condensate from oxygen corrosion. A residual of sulfite or other.

Oxygen scavenger in the boiler cannot chemically reduce all of the oxygen before it escapes with the steam or reacts with the metal surfaces.

Turbocharger cleaning chemicals

Turbocharger cleaning chemicals

Turbocharger cleaning chemicals for removal of oil grease, carbon residue etc... ACC 9 is a blend of powerful, penetrating emulsifying solvent, Which is resulting emulsion when mixing with water. ACC9 After mixing with water works as an aggressive emulsion cleaner for the cleaning of diesel engine air coolers, scavenging air systems and compressor sides of turbochargers etc... 

Air cooler cleaner MSDS and Technical Bulletine as well as dose and using procedure are available on this link...

Metal Clean Bright as a Aluminium Cleaner

Metal Clean Bright as a Aluminium Cleaner

Aluminium Oxide also can be remove by using Metal Clean Bright diluted solution 10 to 30% . During cleaning application it is very important to take care each and every effect of Metal Clean Bright with aluminium. Maximum cotact time of Aluminimu with Metal Clean Bright should be 2 - 7 Minutes. Otherwise our product list have specizalized products for cleaning of aluminum RXSOL-16-1028-025  .

Powerful Solid Aluminium Cleaner

Copyright © 2021 Powered By RXMARINE - All Rights Reserved