Rocor NB Liq Corrosion Scale Inhibitor

COOLING WATER CORROSION & SCALE INHIBITOR Corrosion Inhibitor for Water Systems  having  unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous c [+] Read More...
Active Matter:

68 - 75%

Packing Size:
25.00 Ltr.
Code:
RXSOL-40-4001-025
For INDIA based requirement mail us at rxmarine@gmail.com  or you may call us +91 22 65113333 / 65115555 / 65119999  while  For Gulf Middle East email id id  dubichem@gmail.com  & Tel No.   00971 9 2242524 / 2242534 We are Operational at following location with STOCK POINT Surat, Kandla, Gandhidham, Mundra, Hazira, Tata, Ranchi, Kolkata, Haldia, Buz Buz, Paradip, Vizag ( Visakhapatnam ), Tuticorin, Cochin, Goa, Mumbai, JNPT, Pirpav, Chennai, Ennore, Fujairah, Sharjah, Dubai, Middle East  

 

Rocor NB Liq Corrosion Scale Inhibitor
Application:
Prolongs the life of equipment by keeping it scale and corrosion free. Since RXSOL-40-4001-025 is alkaline, it will suppress acid corrosion, which would otherwise result in sever pittings. It improves [+] Read More...
Using Procedure:
Refer to technical datasheet. GENERAL RECOMMENDATION : ( The dosage chart may be used as a guide to adjust treatment to obtain the optimum level.) Nitrite (as PPM NO2) 0  100 [+] Read More...
Note:
Initial dosage for an untreated system is 9 litres of RXSOL-40-4001-025 / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result [+] Read More...
Technical Specifications:

RX MARINE INTERNATIONAL are continiously working in water treatement sector, And developed many unique product to avoid corrosion and scale depositon in cooling water system. Here I wants to keep our experiment results with you.Corrosion inhibitor for closed cooling systems containing molybdate/phosphonate ( RXSOL-40-4018-025 ). Sodium molybdate has the advantage in that the dosing of lower ppm's of molybdate allow for lower conductivity of the circulating water. Sodium molybdate at levels of 50-100 ppm offer the same levels of corrosion inhibition that sodium nitrite at levels of 800+ ppm. By utilizing lower concentrations of sodium molybdate, conductivity is kept at a minimum and thus galvanic corrosion potentials are decreased.

Precaution:

Before testing of Nitrite level, Here is some point and guideline,  what you need to do. : 1 take the following readings; pH, TDS (uS), and nitrite level.and record. 2 add the Chemical your are using. 3. wait for a period of time for the sysem to circulate. hours> 4. Re check the readings. and record. 5 track these readings
for a period of time.

If the TDS and Nitrite drop you have a leak/ unknown makeup. if the TDS stays stable and the nitrite drops you have a biological problem. Bacteria that convert nitrite to nitrate.

Solution ::: Use DI water in place of general water, And also use. Algaecide to control Bacterial growth inside water system ... http://rxmarine.com/Biocide-Algaecide

Rocor NB Liq Corrosion Scale Inhibitor
Rocor NB Liq Corrosion Scale Inhibitor
Rocor NB Liq Corrosion Scale Inhibitor