PROCEDURE for test ( STEP WISE ):

  1. Measure 15 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER
  2. Add 1-2 drops of  RXSOL TK1 and mix with the stirring rod , If  sample turns red / PINK then follows 3rd step otherwise if sample remains colourless proceed to step 4.
  3. Add RXSOL TK2  drop by drop , mixing with the stirring rod until colour just disappears.
  4. Add 3 drops of RXSOL TK3 and mix with stirring rod , the sample will turn YELLOW.
  5. AddRXSOL TK4 carefully by counting drop by drop and mixing throughly until a light reddish / pink / brown colour develop.

RX MARINE INTERNATIONAL is most popular chemicals source in INDIA, Keeping ready stock at 5 LOCATION which includes Mumbai, Kandla - Gandhidham, Vizag - Visakhapatnam, Ennore - Chennai, Kolkata more then 3000 types of chemicals. Please click here to get PRODUCT Categories details http://rxmarine.com/Products

 

Mail Us for any PRODUCT related information and purchase inquiry : mail@rxmarine.com ( This mail is for customer / Buyer only ) And if you wants to add your hand as a supplier, And if you have volume manufacturing capacity of chemicals, pl. drop your mail at rxmarine@gmail.com ( This mail is for supplier only )