Product Application

. 0,1,2,3,4,5,6 drops of Standard sodium fluoride solution was taken in 7 test tubes using a calibrated pipette. 

. Add 20,19,18,17,16,15 and 14 drops of distilled water in to the above tubes so that the volume in each tube is 20 mL. with the pipette. 

. Rinse the pipette and 20 drops of sample water was taken in a different test tube with the same pipette. 

RX MARINE INTERNATIONAL is most popular chemicals source in INDIA, Keeping ready stock at 5 LOCATION which includes Mumbai, Kandla - Gandhidham, Vizag - Visakhapatnam, Ennore - Chennai, Kolkata more then 3000 types of chemicals. Please click here to get PRODUCT Categories details http://rxmarine.com/Products

 

Mail Us for any PRODUCT related information and purchase inquiry : mail@rxmarine.com ( This mail is for customer / Buyer only ) And if you wants to add your hand as a supplier, And if you have volume manufacturing capacity of chemicals, pl. drop your mail at rxmarine@gmail.com ( This mail is for supplier only )

 

 

Fluoride Test Kit Manufacturer

Fluoride Test Kit Exporter

Fluoride Test Kit Supplier